For Roof Venting Installation Only
1.Insert damper assembly through the cabinet cutout so that the long tab of the damper assembly slides into the slot on the left side of the damper vent opening, as shown. Then secure with mounting screw.
NOTE: The screw cannot be installed if the damper assembly is not positioned as shown.
ABC
D
A. Long tab (inside slot)
B. Damper assembly
C. Mounting screw
D. Upper cabinet cutout
2.Connect vent to damper assembly.
A B
A.Vent
B.Damper assembly (under vent)
Complete Installation
1.Refer to the Use and Care Guide for instructions on how to install filters into your model.
WARNING
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death, fire, or electrical shock.
2.Plug microwave oven into grounded 3 prong outlet.
3.Reconnect power.
4.Check the operation of microwave oven by placing 1 cup
(250 mL) of water on the turntable, and programming a cook time of 1 minute at 100% power. Test vent fan and exhaust by operating the vent fan.
5.If the microwave oven does not operate:
■Check that a household fuse has not blown, or that a circuit breaker has not tripped. Replace the fuse or reset the circuit breaker. If the problem continues, call an electrician.
■Check that the power supply cord is plugged into a grounded 3 prong outlet.
■See the Use and Care Guide for troubleshooting information.
Installation is now complete.
Save Installation Instructions for future use.