KitchenAid W10189714A, W10190011A Mark Rear Wall, Drill Holes in Rear Wall

Page 7

Mark Rear Wall

The microwave oven must be installed on a minimum of 1 wall stud, preferably 2, using a minimum of 1 lag screw, preferably 2.

1.Using measuring tape, find and clearly mark the vertical centerline of the opening.

A

A.Centerline

2.With the support tabs facing forward (see illustrations in “Possible Wall Stud Configurations” in “Locate Wall Stud(s)” section), align the mounting plate center markers to the centerline on the wall, making sure it is level, and that the top of the mounting plate is butted up against the bottom edge of the upper cabinet.

NOTE: If the front edge of the upper cabinet is lower than the back edge, lower the mounting plate so that its top is level with the front edge of the cabinet.

D

A

C

B

A. Rear wall

B. Mounting plate

C. Top of mounting plate must align with front edge of cabinet.

D. Front edge of upper cabinet

3.Holding the mounting plate in place, mark both bottom corner holes.

4.Find the wall stud centerline(s) marked in Step 2 of “Locate Wall Stud(s),” and mark at least 1, preferably 2, hole(s) through the mounting plate, closest to the centerline(s). See figures 1, 2 and/or 3 in “Possible Wall Stud Configurations” in “Locate Wall Stud(s)” section. The blackened holes in the shaded areas are ideal hole locations.

5.Set mounting plate aside.

Wall Venting Installation Only

Centerline

Upper cabinet bottom

 

³⁄₈" (1 cm)

4" (10.2 cm)

 

6" (15.2 cm)

6" (15.2 cm)

6.Mark the centerline 3/8" (1 cm) down from the bottom edge of the upper cabinet.

7.Using measuring tape, measure out 6" (15.2 cm) on both sides of the centerline, and mark.

8.Measure down 4" (10.2 cm) from the mark made in Step 6, and mark.

9.Using a straightedge, draw the 2 horizontal, level lines through the marks made in steps 6 and 8.

10.Draw the 2 vertical, plumb lines down from the marks made in Step 7 to complete the 12" x 4" (30.5 x 10.2 cm) rectangle. This is the venting cutout area.

11.Cut a 3/4" (19 mm) hole in one corner of the cutout area.

12.Using a keyhole saw, cut out the venting cutout area.

Drill Holes in Rear Wall

In addition to being installed on at least 1 wall stud, the mounting plate must attach to the wall at both bottom corner holes. If the holes are not over wall studs, use two 1/4-20 x 3" round-head bolts with toggle nuts; if 1 hole is over a wall stud, use 1 lag screw and one 1/4-20 x 3" round-head bolt with toggle nut; or if both holes are over wall studs, use 2 lag screws. Following are

3 installation configurations.

Installation for No Wall Studs at Corner Holes (Figures 1 & 2)

1.Drill 3/4" (19 mm) holes through the wall at both bottom corner holes marked in Step 3 of “Mark Rear Wall.”

2.Drill 3/16" (5 mm) hole(s) into the wall stud(s) at the hole(s) marked in Step 4 of “Mark Rear Wall.” Refer to figures 1 and 2 in “Possible Wall Stud Configurations” in “Locate Wall Stud(s)” section.

Installation for Wall Stud at One Corner Hole (Figure 3)

1.Drill a 3/16" (5 mm) hole into the wall stud at the corner hole marked in Step 3 of “Mark Rear Wall.”

2.If installing on a second wall stud, drill a 3/16" (5 mm) hole into the wall stud at the other hole marked in Step 4 of “Mark Rear Wall.” Refer to Figure 3 in “Possible Wall Stud Configurations” in “Locate Wall Stud(s)” section.

3.Drill a 3/4" (19 mm) hole through the wall at the other corner hole.

Installation for Wall Studs at Both Corner Holes (Figure 4)

1.Drill 3/16" (5 mm) holes into the studs at the corner holes marked in Step 3 of “Mark Rear Wall.”

7

Image 7
Contents Microwave Hood Combination Safety Microwave Hood Combination Installation InstructionsTools and Parts Installation RequirementsLocation Requirements Required Product DimensionsInstallation Dimensions Electrical RequirementsConvert Microwave Oven to External Venting Installation InstructionsTo Install Vent Deflector Remove Mounting PlateC D Locate Wall Studs Possible Wall Stud ConfigurationsDrill Holes in Rear Wall Mark Rear WallWall Stud at One Corner Hole Figure Attach Mounting Plate to WallPrepare Upper Cabinet No Wall Studs at Corner Holes Figures 1For Roof Venting Installation Only Install the Microwave OvenComplete Installation Recommended Standard Fittings Venting Design SpecificationsFor optimal venting installation, we recommend Rectangular to Round Transition¹⁄₄ x 10 8.3 x 25.4 cm vent system = 73 ft 22.2 m total Replacement PartsAssistance Recommended Vent Length