KitchenAid W10189714A, W10190011A installation instructions C D

Page 5

3.When the vent deflector is as far back as it can easily slide, flip it so that the wide side is to the back of the microwave oven, and the narrow side (with holes) is down. The vent deflector holes should align with mounting holes in the vent opening, as shown in inset.

A B

A. Vent opening

B. Vent deflector

4.Secure vent deflector with 2 mounting screws (1 on each end).

A B

A. Mounting screw

B. Vent deflector

5.Replace vent screen.

Wall Venting Installation Only

To Remove Wall Damper Vent Cover:

1.Locate the wall damper vent cover on the back of the microwave oven.

2.Using diagonal wire cutting pliers, gently snip out the damper vent cover at the perforations.

A B C D

A. Diagonal wire cutting pliers

B. Back of microwave oven

C. Wall damper vent cover

D. Perforations

3.Save the cover for possible change of venting method in the future.

4.Position the damper assembly so that the long tab slides into the slot on the right side of the damper vent opening, as shown. Then secure with mounting screw.

A BC

A. Mounting screw

B. Damper assembly

C. Long tab (inside slot)

Roof Venting Installation Only

To Remove Roof Damper Vent Cover:

1.Locate the roof damper vent cover on the top of the microwave oven.

2.Using diagonal wire cutting pliers, gently snip out the damper vent cover at the perforations.

AB C

D

A. Diagonal wire cutting pliers

B. Top of microwave oven

C. Roof damper vent cover

D.Perforations

3.Save the cover for possible change of venting method in the future.

NOTE: Do not install damper assembly at this time.

5

Image 5
Contents Microwave Hood Combination Safety Microwave Hood Combination Installation InstructionsLocation Requirements Installation RequirementsTools and Parts Installation Dimensions Product DimensionsElectrical Requirements RequiredTo Install Vent Deflector Installation InstructionsRemove Mounting Plate Convert Microwave Oven to External VentingC D Locate Wall Studs Possible Wall Stud ConfigurationsDrill Holes in Rear Wall Mark Rear WallPrepare Upper Cabinet Attach Mounting Plate to WallNo Wall Studs at Corner Holes Figures 1 Wall Stud at One Corner Hole FigureFor Roof Venting Installation Only Install the Microwave OvenComplete Installation For optimal venting installation, we recommend Venting Design SpecificationsRectangular to Round Transition Recommended Standard FittingsAssistance Replacement PartsRecommended Vent Length ¹⁄₄ x 10 8.3 x 25.4 cm vent system = 73 ft 22.2 m total