KitchenAid KUD-22 manual Connecting the Water Supply Line

Page 10

To maintain dishwasher position and alignment, locate the adjustable brackets at the upper tank corners as shown on Fig. 13 and secure them to the countertop with self-drilling flat head wood screws (supplied). Drill a pilot hole to a %I” (19 mm) maximum depth in the centre of the bracket mounting hole using a l/e” (3 mm) drill bit. DO NOT exceed %” (19 mm) depth. NOTE: Make sure screw heads will not interfere with the top of the door. If these brackets are not compatible with your countertop, the dishwasher may be anchored to the floor, with a l/4” (6 mm) lag bolt (not supplied), through the hole in each side of the dishwasher frame as shown in Fig. 12.

Adjustable bracket

m mstallat~on posltlon ,

Flat head wood screw

Fig. 13

4 CONNECTING THE WATER SUPPLY LINE

The water supply line should be flushed to clear any foreign material BEFORE connecting to dishwasher.

Make sure there are no sharp bends or kinks which might restrict ,Nater flow

To facilitate connection of the water line from the rear of the dishwasher it is recommended that a Ye” (9.5 mm) NPT street elbow be connected to the fill valve and a 90’ compression elbow (Ye” (9.5 mm) NPT one end) be connected to the street elbow. The supply line can then be connected to the compression elbow (see Fig. 14). NOTE: If galvanized pipe is used, substitute a second 3/a” (9.5 mm) street elbow and l/2” (13 mm) NPT and Ye” (9.5 mm) NPT reducing adaptor for the compression elbow.

Turn on water supply and check for leaks

Compresslon flu1

Compresslon sleeve .,

%I* (16 mm) O.D. copper

water line

90” cc;mpresslon elbow -~ (VS (9.5 mm) NPT one end)

DIshwasher fill valve

Fig. 14

Image 10
Contents KUD-22 Series Dish Washers Thispage YOU will Need These Tools Before StartingAA/D These Materials Specifications Here are the Basic Steps of InstallationChoosing the Loca T/ON Preparing the Location ~~ --y-- --- ~~~ ‘LJ Placing the Dishwasher in ITS Location Rear Cross Channel Adjustment Connecting the Water Supply Line Connecting the Drain Line Connecting the Electrical SupplyFinal Check List Front Panel Variations ‘/4THK.@mm7rSeasonal Storage KitthenAid7’ 11 l This Intentionally Left Blank Owls NkESSAIRES Pour L’INSTALLATION Avant DE CommencerVoici LES Principales /iTAPES DE L’INSTALLATlON Fiche TechniqueChoix DE L’EMPLACEMENT ’rwPreparation DE L’EMPLACEMENT Conduit D‘hACUATION Mise EN Place DU LAVE-VAISSELLE RiGLAGEDE LABARRETRANSVERSALEARRItRE Raccordement DU Conduit DflLIMENTATlON EN EAU Raccordement DU Conduit D’&ACUATlON Raccordement GlectriquePlaque pare-pieds Rkglable VARiAN7ES DU F’ANNEAU Avant KitthenAid’