KitchenAid KUD-22 manual Rear Cross Channel Adjustment

Page 9

REAR CROSS CHANNEL ADJUSTMENT

Slide the dishwasher into the cabinet opening, being careful to avoid damage to the floor or interference with water, drain, and electrical lines. DO NOT remove the rear cross channel, unless there is an interference with the plumbing lines. In most cases, any plumbing interference can be eliminated by raising one side of the rear cross channel. (See Fig. 10 for details.)

Back of dlshwasher

Rear cross channel

I” alternate pos~llon

SteD Looser

lhls SC’YW _

SleD Remove

lhls screw. _

Fig. 10a

Line up the lower cross channel hole with ihe upper hole in frame

Fasten securely Tighten the

.screw at other end.

-Step 1 ~ Remove

these screw’ s.

cross channel lglnal posltlon

Unlatch and open the door and remove the foam shipping cushions from uppelr corners of the door. Check to ensure that cabinet clearance is equal on both sides of the dishwasher and that cabinet interference does not distort dishwasher tank.

With the door still open, place a spirit/bubble level against the front tank flange (Fig. 11) and level the dishwasher front-to-backand side-to-side by adjusting the leveling legs (Fig. 12) In or out as necessary.

Adjustable bracket in shlpolng posltlon

>

Fig. 11

If the dishwasher is not properly leveled or if it is distorted by cabinet interference, the door may not seal properly and may leak. If necessary, the leveling leg may be further adjusted to correct any distortion and align tank for equal clearance on both sides (Fig. 12).

-9-

Image 9
Contents KUD-22 Series Dish Washers Thispage Before Starting YOU will Need These ToolsAA/D These Materials Here are the Basic Steps of Installation SpecificationsChoosing the Loca T/ON Preparing the Location ~~ --y-- --- ~~~ ‘LJ Placing the Dishwasher in ITS Location Rear Cross Channel Adjustment Connecting the Water Supply Line Connecting the Electrical Supply Connecting the Drain LineFinal Check List ‘/4THK.@mm7r Front Panel VariationsKitthenAid Seasonal Storage7’ 11 l This Intentionally Left Blank Avant DE Commencer Owls NkESSAIRES Pour L’INSTALLATIONFiche Technique Voici LES Principales /iTAPES DE L’INSTALLATlON’rw Choix DE L’EMPLACEMENTPreparation DE L’EMPLACEMENT Conduit D‘hACUATION Mise EN Place DU LAVE-VAISSELLE RiGLAGEDE LABARRETRANSVERSALEARRItRE Raccordement DU Conduit DflLIMENTATlON EN EAU Raccordement Glectrique Raccordement DU Conduit D’&ACUATlONPlaque pare-pieds Rkglable VARiAN7ES DU F’ANNEAU Avant KitthenAid’