KitchenAid W10271686B GAS Conversions, LP Gas Conversion, To Convert Gas Pressure Regulator

Page 14

GAS CONVERSIONS

IMPORTANT: Gas conversions from Natural gas to LP gas must be done by a qualified installer.

WARNING

Explosion Hazard

Use a new CSA International approved gas supply line.

Install a shut-off valve.

Securely tighten all gas connections.

If connected to LP, have a qualified person make sure gas pressure does not exceed 14" (36 cm) water column.

Examples of a qualified person include:

licensed heating personnel,

authorized gas company personnel, and authorized service personnel.

Failure to do so can result in death, explosion, or fire.

LP Gas Conversion

1.Turn the manual shutoff valve to the closed position.

2.Unplug cooktop or disconnect power.

B

A

C

A. To cooktop

B. Shutoff valve (closed position)

C. Gas supply line

.

A

B

E

D

C

A. Access cap

 

D. LP position

B. Gasket

 

E. NAT position

C. Gas pressure regulator

3.Test the gas pressure regulator and gas supply line.

The regulator must be checked at a minimum 1" (2.5 cm) water column above the set pressure. The inlet pressure to the regulator should be as follows for operation and checking the regulator setting:

LP Gas:

Minimum pressure 11" (27.9 cm) WCP Supply pressure 14" (35.5 cm) WCP

Gas Supply Pressure Testing

Gas supply pressure for testing regulator must be at least 1" water column pressure above the manifold pressure shown on the model/serial rating plate.

Line pressure testing above ½ psi gauge (14" WCP)

The cooktop and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of ½ psi (3.5 kPa).

Line pressure testing at ½ psi gauge (14" WCP) or lower

The cooktop must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than ½ psi (3.5 kPa).

To Convert Gas Pressure Regulator

1.Remove the access cap by using a wrench, turning the access cap counterclockwise.

2.Remove spring retainer from the cap by pushing against the flat side of the spring retainer. Look at the spring retainer to locate the “NAT” or “LP” position. Turn over the spring retainer so the “LP” is showing on the bottom. Snap the spring retainer back into the cap. Reinstall the cap onto the regulator.

To Convert Surface Burners

1.If installed, remove the burner grates.

2.Remove burner cap.

3.Remove the burner head.

NOTE: A ⁷⁄₈" socket must be used to remove the burner head of the large dual burners.

4.Using a T15 Torx® screwdriver, remove the burner base.

Large Dual Burner

AA. Burner cap

BB. Burner head

C

C. Gas opening

D

D. Burner base

 

14

Image 14 Contents
Pour utilisation résidentielle uniquement W10271686BTable of Contents Table DES MatièresCooktop Safety Your safety and the safety of others are very importantLocation Requirements Installation RequirementsTools and Parts Gas and Electric Connection Locations Product DimensionsSide View of Cooktop Cabinet Requirements KGCU484Type of Gas Electrical RequirementsGas Supply Requirements Natural GasGas Pressure Regulator Gas Supply Pressure TestingGas Supply Line Burner Input Rating AltitudeInstall Optional Backguard Installation InstructionsInstall Cooktop Make Gas Connection Typical flexible connection Complete ConnectionInstall Grill Grease Trays on grill models Install Griddle Complete InstallationOn Griddle Models LP Gas Conversion Gas Supply Pressure TestingGAS Conversions To Convert Gas Pressure RegulatorReplace Igniter Small Surface Burners Only Burner orifice spud Grill orifice hoodTo Convert Grill Burner on some models Complete InstallationNatural Gas Conversion Natural Gas Orifice Spud/Hood Chart Burner Rating Size Burner Style 000 BTU 01 mm Small burnersGriddle 120V Control Wiring Diagram To Cooktop Stand-Alone Strip CircuitsWiring Diagrams Burners Cooktop Reignition Wiring DiagramBurner Cooktop Reignition Wiring Diagram Sécurité DE LA Table DE Cuisson Votre sécurité et celle des autres est très importanteExigences D’INSTALLATION Outillage et piècesExigences demplacement Dimensions du produitEmplacements des raccordements au gaz et à lélectricité Vue latérale de la table de cuissonSpécifications du placard Type de gaz Spécifications électriquesSpécifications de lalimentation en gaz Gaz naturelCaractéristiques dalimentation du brûleur Canalisation de gazDétendeur Test de pressurisation de la canalisation de gazInstallation du dosseret facultatif Instructions D’INSTALLATIONInstallation de la table de cuisson Raccordement au gazRaccordement typique par raccord flexible Compléter le raccordementInstallation des plateaux à graisse du gril Sur les modèles de grilSi vous avez besoin d’assistance ou de service Installation de la plaque à frireAchever linstallation Si les brûleurs ne sallument pas correctementSur les modèles avec plaque à frire Réglage de la taille des flammesSur les modèles de gril Conversion du détendeur Conversions Pour Changement DE GAZConversion pour lalimentation au propane Gicleur de brûleur Injecteur femelle du gril Conversion des brûleurs de surfaceTest de pressurisation de la canalisation de gaz Achever linstallation Conversion du brûleur du gril sur certains modèlesConversion pour lalimentation au gaz naturel 18 000 BTU 93 mm Brûleur du gril Schéma DES Circuits Schéma DE Câblage LégendeW10271686B MAR SW3 SW4 NEU