Table 33. E-port isolation causes and fixes

Isolation cause

Fix

 

 

Two switch modules in the same fabric

Correct the domain IDs on the malfunctioning switch modules.

have the same domain ID

Domain IDs are decimal numbers in the range from 1 to 239.

 

Domain IDs must be unique.

 

 

All switch modules in the fabric do not

Correct the timeout values on the malfunctioning switch modules.

have the same timeout values

 

 

 

When merging two fabrics, the active

Deactivate one of the active zone sets or edit the conflicting zones

zone sets contain zones with the same

so that their membership is the same. The conflicting zones have

names but different membership.

the same name but different membership. Take the affected ports

 

offline then back online to restore the interswitch links.

 

 

Port fault LED flash patterns

The amber port fault LED is lit to indicate that the port has failed one of the following port operational tests performed with the SAN Utility or the CLI:

Internal

External

Online

If the port fault LED is lit, take the port offline and contact your technical support representative.

Port testing

The port loopback tests verify correct port operation by sending a test data frame out through the loop and then verifying that the frame received matches the frame that was sent. You can perform the following port tests from the Port Loopback window:

Internal SerDes test (internal and external ports) - The SerDes (serializer/deserializer) level test verifies internal and external port circuitry. The SerDes level test sends a test frame from the ASIC through the SerDes chip and back to the ASIC for the selected internal ports. The port passes the test if the frame that was sent by the ASIC matches the test frame that was received.

NOTE

A loopback plug is required to perform an external SFP test.

External SFP test (external ports only) - The SFP level test also verifies port circuitry. The SFP level test sends a test frame from the ASIC through the SerDes chip, through the SFP module fitted with the loopback plug, and back to the ASIC for the selected external ports. The external port passes the test if the test frame that was sent by the ASIC matches the test frame that was received.

Online node-to-node test (internal ports) - The node-to-node test verifies communications between the port and its device node or device loop. The port being tested must be online and connected to a device. The port passes the test if the test frame that was sent matches the test frame that was received.

124Intel Blade Server Switch Module SBCEFCSW Management and User’s Guide

Page 138
Image 138
Intel SBCEFCSW manual Port testing, Port fault LED flash patterns, E-portisolation causes and fixes