4.Choose one of the two types of port loopback tests to run:

To run an internal loopback test, type the following command: test x internal

To run an external loopback test, type the following command. A loopback plug must be installed for this test to pass.

test x external

NOTE

The external loopback test can be performed only on external switch module ports.

After the test type has been chosen and the command executed, a message on the screen will appear detailing the test results.

5.After the test is run, put the port back into online state by typing the following command (x = port number):

set port x state online

6.To verify the port is back online, type the following command. The contents of the AdminState field should be Online.

show port x

The online node-to-node test can test only one port at a time, and that port must be online and connected to an external device or a blade server Fibre Channel expansion card. To run the online node-to-node test, complete the following steps:

1.To start an admin session, type the following command: admin start

2.To run the online node-to-node test, type the following command: test x online

A series of test parameters are displayed on the screen.

3.Press the Enter key to accept each default parameter value, or type a new value for each parameter and press the Enter key. The TestLength parameter is the number of frames sent, the FrameSize (256 byte maximum in some cases) parameter is the number of bytes in each frame, and the DataPattern parameter is the pattern in the payload. Before running the test, make sure that the device attached to the port can handle the test parameters.

FCSM (admin) : user1> test x online

A list of attributes with formatting and current values will follow.

Enter a new value or simply press the ENTER key to accept the default value. If you wish to terminate this process before reaching the end of the list press 'q'

or 'Q' and the ENTER key to do so.

TestLength

(decimal value, 1-4294967295)

[100

]

FrameSize

(decimal value, 36-2148)

[256

]

DataPattern

(32-bit hex value or 'Default')

[Default]

StopOnError

(True/False)

[False

]

Do you want to start the test? (y/n) [n]

4.After all parameter values are defined, press the Y key to start the test.

60Intel Blade Server Switch Module SBCEFCSW Management and User’s Guide

Page 74
Image 74
Intel SBCEFCSW manual test x external