Intel SBCEFCSW manual AMapping port locations and software numbering, Port mapping

Models: SBCEFCSW

1 156
Download 156 pages 18.47 Kb
Page 145
Image 145
AMapping port locations and software numbering

AMapping port locations and software numbering

Your switch module has two external Fibre Channel ports (external Fibre Channel port 1 and external Fibre Channel port 2) and 14 internal Fibre Channel ports that connect to each of the 14 blade server bays (ports 1 to 14). The SAN Utility and CLI for the switch module require port numbering from 0 to 15. The SNMP monitoring agent for the switch module numbers the ports from 1 to 16.

Port mapping

Table 37 shows the mapping of switch module port numbering and whether the port has the capability to be configured.

Table 37. Port mapping

Switch module physical port

SAN Utility and CLI logical

SNMP port

Configurable

connection

port number

numbering

 

 

 

 

 

External port 1

0 (Ext1:0*)

1

Yes

 

 

 

 

Blade server bay 1

1

2

No

 

 

 

 

Blade server bay 2

2

3

No

 

 

 

 

Blade server bay 3

3

4

No

 

 

 

 

Blade server bay 4

4

5

No

 

 

 

 

Blade server bay 5

5

6

No

 

 

 

 

Blade server bay 6

6

7

No

 

 

 

 

Blade server bay 7

7

8

No

 

 

 

 

Blade server bay 8

8

9

No

 

 

 

 

Blade server bay 9

9

10

No

 

 

 

 

Blade server bay 10

10

11

No

 

 

 

 

Blade server bay 11

11

12

No

 

 

 

 

Blade server bay 12

12

13

No

 

 

 

 

Blade server bay 13

13

14

No

 

 

 

 

Blade server bay 14

14

15

No

 

 

 

 

External port 2

15 (Ext2:15*)

16

Yes

 

 

 

 

* Indicates a symbolic port name if it is different from the logical port number.

NOTE

The Fibre Channel ports that connect to each of the blade server bays (1 through 14) are fixed 2 Gbps F_Port configurations. Only the administrative state for these ports can be changed.

131

Page 145
Image 145
Intel SBCEFCSW manual AMapping port locations and software numbering, Port mapping