Table 10. Set Config zoning parameters

Parameter

Description

 

 

AutoSave

Determines whether zoning changes will be saved to flash (nonvolatile) memory

 

(On) or to RAM (volatile) (Off). The default is On.

 

 

Default

Determines communication among ports/devices in the absence of an active zone

 

set. “All” enables all ports/devices to communicate with one another. “None”

 

prohibits communication among ports/devices.

 

 

Examples

The following is an example of the Set Config Port command.

FCSM: user1> admin start

FCSM (admin) : user1> config edit

FCSM (admin-config) : user1> set config port 0

A list of attributes with formatting and current values will follow.

Enter a new value or simply press the ENTER key to accept the current value. If you wish to terminate this process before reaching the end of the list press 'q' or 'Q' and the ENTER key to do so.

Configuring Port Number: 0

------------------------

AdminState

(1=Online, 2=Offline, 3=Diagnostics, 4=Down)

[Online

]

LinkSpeed

(1=1Gb/s, 2=2Gb/s, 3=Auto)

[Auto

]

PortType

(TL / GL / G / F / FL / Donor)

[GL

]

TLPortMode

(1=TLTargetMode, 2=TLInitiatorMode)

[TLTargetMode]

ISLSecurity

(Any / Ours / None)

[Any

]

SymPortName

(string, max=32 chars)

[Port0

]

ALFairness

(True /

False)

[False

]

ARB_FF

(True /

False)

[False

]

InteropCredit

(decimal value, 0-255)

[0

]

ExtCredit

(dec value, increments of 11, non-loop only)

[0

]

FANEnable

(True /

False)

[True

]

LCFEnable

(True /

False)

[False

]

MFSEnable

(True /

False)

[True

]

MFS_TOV

(decimal value, 10-20480 msec)

[10

]

MSEnable

(True /

False)

[True

]

NoClose

(True /

False)

[False

]

IOStreamGuard

(Enable

/ Disable)

[Disabled

]

VIEnable

(True /

False)

[False

]

CheckAlps

(True /

False)

[False

]

Finished configuring attributes.

 

 

This configuration must be saved (see config save command)

and

 

activated (see config

activate command) before it can take

effect.

 

To discard this configuration use the config cancel command.

The following is an example of the Set Config Switch command.

32Intel Blade Server Switch Module SBCEFCSW Management and User’s Guide

Page 46
Image 46
Intel SBCEFCSW Examples, Set Config zoning parameters, AutoSave, On or to RAM volatile Off. The default is On, Default