Intel SBCEFCSW manual Examples, System configuration settings

Models: SBCEFCSW

1 156
Download 156 pages 18.47 Kb
Page 54
Image 54

Table 12. System configuration settings

Entry

Description

 

 

Eth0NetworkAddress

Ethernet Internet protocol (IP) address

 

 

Eth0NetworkMask

Ethernet subnet mask address for the Ethernet port.

 

 

Eth0GatewayIPAddress

Ethernet IP address gateway

 

 

Eth0NetworkDiscovery

Ethernet boot method (1 - Static).

 

Note: BootP, DHCP, and RARP do not apply

 

 

AdminTimeout

Specifies the amount of time in minutes the switch waits before terminating an

 

idle Admin session. Zero (0) disables the time out threshold. The default is 30;

 

the maximum is 1440.

 

 

Security Enabled

Enables or disables the enforcement of account names and passwords.

 

 

Remote Log Enabled

Whether remote logging is enabled or disabled. If enabled, log information is

 

saved to a remote host that supports the syslog protocol.

 

 

RemoteLogHost IP Address

The IP address of the host that will receive the remote log information if

 

remote logging is enabled.

 

 

NOTE

The two components of security are user authentication and fabric security. The user must be authenticated before gaining access to a switch. If an invalid account name/password combination is entered, that user can not access the switch, and thus cannot gain access to the fabric. If security is enabled (True) and a valid account name/password combination is entered, that user can access the switch but can not execute any command that exceeds their authority (privileges) level. If security is disabled (False) and a valid account name/password combination is entered, that user has access to all switches in the fabric and can execute all commands (both user and admin), regardless of their authority (privileges) level.

Examples

The following is an example of the Set Setup SNMP command.

FCSM: user1> admin start

FCSM (admin) : user1> set setup snmp

A list of attributes with formatting and current values will follow.

Enter

a new

value or

simply press the

ENTER key to accept

the

current value.

If you wish

to terminate

this process

before

reaching the

end

of the list

press

'q' or 'Q' and

the

ENTER key to

do so.

 

 

 

Trap Severity Options

 

 

---------------------

 

 

unknown, emergency,

alert, critical, error, warning, notify, info, debug, mark

Contact

(string, max=32 chars)

[<sysContact undefined> ]

Location

(string, max=32 chars)

[<sysLocation undefined>]

Trap1Address

(dot-notated IP Address)

[10.0.0.1

]

Trap1Port

(decimal value)

[162

]

Trap1Severity

(see allowed options above)

[warning

]

Trap1Enabled

(True / False)

[False

]

40Intel Blade Server Switch Module SBCEFCSW Management and User’s Guide