Intel SBCEFCSW manual Show Port parameters, Entry, Description

Models: SBCEFCSW

1 156
Download 156 pages 18.47 Kb
Page 58
Image 58

Table 13. Show Port parameters

Entry

Description

 

 

AIinit

Incremented each time the port begins AL initialization.

 

 

AIinitError

Number of times the port entered initialization and the initialization failed.

 

 

ClassXFramesIn

Number of class x frames received by this port.

 

 

ClassXFramesOut

Number of class x frames sent by this port.

 

 

ClassXWordsIn

Number of class x words received by this port.

 

 

ClassXWordsOut

Number of class x words sent by this port.

 

 

DecodeError

Decoding error detected.

 

 

EpConnects

Number of times an E_Port connects through ISL negotiation.

 

 

FBusy

Number of times the switch sent a F_BSY because Class 2 frame could not be

 

delivered within ED_TOV time. Number of class 2 and class 3 fabric busy

 

(F_BSY) frames generated by this port in response to incoming frames. This

 

usually indicates a busy condition on the fabric or N_port that is preventing

 

delivery of this frame.

 

 

Flowerrors

Received a frame when there were no available credits.

 

 

FReject

Number of frames from devices that were rejected.

 

 

InvalidCRC

Invalid CRC detected.

 

 

InvalidDestAddr

Invalid destination address detected.

 

 

LIP ALPD ALPS

Number of F7, AL_PS LIPs, or AL_PD (vendor specific) resets, performed.

 

 

LIPF7ALPS

This LIP is used to reinitialize the loop. An L_port, identified by AL_PS, may

 

have noticed a performance degradation and is trying to restore the loop.

 

 

LIPF8ALPS

This LIP denotes a loop failure detected by the L_port identified by AL_PS.

 

 

LIPF7F7

A loop initialization primitive frame used to acquire a valid AL_PA.

 

 

LIPF8F7

A loop initialization primitive frame used to indicate that a loop failure has been

 

detected at the receiver.

 

 

Link Failures

Number of optical link failures detected by this port. A link failure is a loss of

 

synchronization for a period of time greater than the value of R_T_TOV or by

 

loss of signal while not in the offline state. A loss of signal causes the switch to

 

attempt to re-establish the link. If the link is not re-established by the time

 

specified by R_T_TOV, a link failure is counted. A link reset is performed after

 

a link failure.

 

 

Login

Time when user logged in.

 

 

Logout

Time when user logged out.

 

 

LoopTimeouts

A 2-second timeout as specified by FC-AL-2.

 

 

LossOfSync

Number of synchronization losses (>100 ms) detected by this port. A loss of

 

synchronization is detected by receipt of an invalid transmission word.

 

 

PrimSeqErrors

Primitive sequence errors detected.

 

 

RxLinkResets

Number of link reset primatives received from an attached device.

 

 

44Intel Blade Server Switch Module SBCEFCSW Management and User’s Guide

Page 58