Intel SBCEFCSW Set Config port parameters continued, Set Config switch parameters, Parameter

Models: SBCEFCSW

1 156
Download 156 pages 18.47 Kb
Page 44
Image 44

Table 7. Set Config port parameters (continued)

Parameter

Description

 

 

SymbolicPortName

Descriptive name

 

 

ALFairness

Default is switch that has priority

 

 

ARB_FF

Use ARB_FF instead of idles on loop FCAL option

 

 

InteropCredit

Number of buffer-to-buffer credits per port. 0 means the default (12) is unchanged.

 

 

ExtCredit

Extended credit port

 

 

FANEnable

Fabric Address Notification. If enabled, notifies logged-in NL_Ports of the FL_Port

 

address, port name, and node name.

 

 

LCFEnable

Link control frame preference, R_CTL = 0xC

 

 

MFSEnable

Multi-frame sequence bundling

 

 

MFS_TOV

MFS limit for camp on

 

 

MSEnable

Management Server enable on this port

 

 

NoClose

Do not close unless another device arbitrates

 

 

I/O Stream Guard

Enables or disables the suppression of RSCN messages

 

 

VIEnable

Not applicable

 

 

CheckAlps

Close before sending frames to new target

 

 

switch

Initiates an editing session in which to change switch configuration settings. Each parameter is displayed, one line at a time and prompts you for a value. For each parameter, type a new value or press the Enter key to accept the current value shown in brackets. Type q to cancel the configuration.

Table 8. Set Config switch parameters

Parameter

Description

 

 

AdminState

Switch administrative state: online, offline, or diagnostics.

 

 

Broadcast Enable

Enables (True) or disables (False) forwarding if broadcasting frames.

 

 

InbandEnabled

Enables (True) or disables (False) the ability to manage the switch over an ISL.

 

 

DefaultDomainID

Default domain ID setting.

 

 

DomainIDLock

Prevents (True) or allows (False) dynamic reassignment of the domain ID.

 

 

SymbolicName

Descriptive name

 

 

R_T_TOV

Receiver Transmitter Timeout Value. Specifies the number of milliseconds a port

 

is to wait to receive a response from another port. The default is 100.

 

 

R_A_TOV

Resource Allocation Timeout Value. The number of milliseconds the switch waits

 

to allow two ports to allocate enough resources to establish a link. The default is

 

10000.

 

 

E_D_TOV

Error Detect Timeout Value. The number of milliseconds a port is to wait for errors

 

to clear. The default is 2000 msec.

 

 

FS_TOV

Fabric Stability Timeout Value. The default is 5000 msec.

 

 

30Intel Blade Server Switch Module SBCEFCSW Management and User’s Guide

Page 44
Image 44
Intel SBCEFCSW manual Set Config port parameters continued, Set Config switch parameters, Parameter, Description