Table 8. Set Config switch parameters (continued)

Parameter

Description

 

 

DS_TOV

Distributed Services Timeout Value (Management Server, Name Server). The

 

default is 5000 msec.

 

 

PrincipalPriority

The priority used in the FC-SW-2 principal switch selection algorithm. 1 is high,

 

255 is low.

 

 

ConfigDescription

The name for the configuration. The default is undefined.

 

 

threshold

Initiates a configuration session by which to generate and log alarms for selected events. Each event, its thresholds, and sampling interval is displayed, one line at a time and you are prompted for a value. For each parameter, enter a new value or press the Enter key to accept the current value shown in brackets. These parameters must be saved in a configuration and activated before they will take effect. See the “Config command” on page 11 for information about saving and activating a configuration. Table 9 describes the Set Config threshold parameters.

Table 9. Set Config threshold parameters

Parameter

 

Description

 

 

Threshold Monitoring Enabled

Master enable/disable parameter for all events. Enables (True) or

 

disables (False) the generation of all enabled event alarms.

 

 

CRCErrorsMonitoringEnabled

The event type enable/disable parameter. Enables (True) or disables

DecodeErrorsMonitoringEnabled

(False) the generation of alarms for each of the following events:

ISLMonitoringEnabled

CRC errors

LoginMonitoringEnabled

Decode errors

LogoutMonitoringEnabled

ISL connection count

LOSMonitoringEnabled

Login errors

 

 

Logout errors

 

Loss-of-signal errors

 

 

Rising Trigger

The event count above which an event is logged. Once the count

 

exceeds the rising threshold, one alarm is logged. The switch will not

 

generate another alarm for that event until the count falls below the

 

falling threshold and rises again above the rising threshold.

 

 

Falling Trigger

The event count above which an event becomes eligible for logging in

 

the alarm log.

 

 

Sample Window

The period of time in seconds in which to count events.

 

 

 

zoning

Initiates an editing session in which to change switch zoning attributes. Each parameter is displayed, one line at a time, and you are prompted for a value. For each parameter, enter a new value or press the Enter key to accept the current value shown in brackets.

31

Page 45
Image 45