MFS_TOV 10

MSEnable True

NoClose False

IOStreamGuard Disabled

VIEnable False

CheckAlps False

The following is an example of the Show Config Switch command.

FCSM: user1> show config switch

Configuration Name: lei

-------------------

Switch Configuration Information

--------------------------------

AdminState

Online

BroadcastEnabled

True

InbandEnabled

True

DomainID

1 (0x1)

DomainIDLock

False

SymbolicName

Fibre Channel Switch Module

R_T_TOV

100

R_A_TOV

10000

E_D_TOV

2000

FS_TOV

5000

DS_TOV

5000

PrincipalPriority

254

ConfigDescription

Fibre Channel Switch Module

ConfigLastSavedBy

Initial

ConfigLastSavedOn

Initial

The following is an example of the Show Config Threshold command.

FCSM: user1> show config threshold

Configuration Name: default

-------------------

Threshold Configuration Information

-----------------------------------

ThresholdMonitoringEnabled

True

CRCErrorsMonitoringEnabled

True

RisingTrigger

25

FallingTrigger

1

SampleWindow

10

DecodeErrorsMonitoringEnabled

True

RisingTrigger

200

FallingTrigger

0

SampleWindow

10

ISLMonitoringEnabled

True

RisingTrigger

2

FallingTrigger

0

SampleWindow

10

LoginMonitoringEnabled

True

RisingTrigger

5

50Intel Blade Server Switch Module SBCEFCSW Management and User’s Guide

Page 64
Image 64
Intel SBCEFCSW manual MFS TOV MSEnable True NoClose False