Cisco Systems 11500 Series Connecting the Console, Connecting the Chassis to Ground, Parameters

Models: 11500 Series

1 184
Download 184 pages 59.76 Kb
Page 76
Image 76
Connecting the Console

Chapter 2 Cabling and Troubleshooting the CSS

Connecting the Console

Connecting the Console

To connect a console to the CSS, attach the console cable (provided in the accessory kit) to the Console port on the CSS. Your terminal settings must match the CSS default settings specified in Table 2-7.

Table 2-7 CSS Console Port Default Settings

Parameters

Default Settings

 

 

Baud

9600

 

 

Data Bits

8

 

 

Parity

None

 

 

Stop Bits

1

 

 

Terminal Type

VT100/ANSI

 

 

Flow Control

None

 

 

If a communications problem occurs between the CSS and a console, see the “Troubleshooting the Console Interface” section later in this chapter.

Connecting the Chassis to Ground

Connecting the CSS 11503 or CSS 11506 chassis to earth ground is required for all DC-powered installations, and any AC-powered installation where compliance with Telcordia (formerly Bellcore) grounding requirements is necessary. Have the recommended tools and supplies available before you begin this procedure (see Table 2-8).

Warning Never defeat the ground conductor or operate the equipment in the absence of a suitably installed ground conductor. Contact the appropriate electrical inspection authority or an electrician if you are uncertain that suitable grounding is available.

 

Cisco 11500 Series Content Services Switch Hardware Installation Guide

2-22

78-13884-06