Chapter 2 Cabling and Troubleshooting the CSS
Troubleshooting the CSS Hardware Components
Table
Symptom | Recommended Action | |
|
| |
At boot up, the following | When there is a failure on a CSS 11501 | |
message appears: | component, the CSS 11501 attempts the boot | |
CHMGR: Slot slot/subslot | process three times. If the boot is unsuccessful, | |
the CSS generates a log message and saves it in | ||
had diagnostic failures - | ||
NOT STARTING UP | the boot.log file. Obtain technical assistance. | |
| Refer to “About This Guide” . For information | |
| on log files, refer to the Cisco Content Services | |
| Switch Administration Guide. | |
|
| |
During normal CSS operation, | Check the six fans in the chassis. The | |
the following message appears: | CSS 11501 is running at a temperature that is | |
Temperature has reached x | too high, as indicated by the x variable. When a | |
fan failure occurs, obtain technical assistance. | ||
celsius for slot number | ||
|
| |
You cannot access log or | Replace the disk containing the files. Remove | |
archive files on the CSS disk but | the disk and install the replacement in the | |
traffic is still passed in and out | CSS 11501. Refer to the reference sheet that | |
of the CSS. | comes with the replacement disk. | |
| After you install the disk in the CSS, you must | |
| wait 10 seconds before you can reseat or | |
| remove it. | |
| If the replacement disk does not have the same | |
| software version that the CSS is running, the | |
| CSS 11501 will not initialize the disk. You | |
| must reboot the CSS and configure a primary | |
| boot record. You can select the CSS software | |
| currently on the disk or instruct the CSS where | |
| to locate the CSS software ADI file to install on | |
| the disk. If you archived an offline version of | |
| your CSS | |
| the CSS. | |
|
|
| Cisco 11500 Series Content Services Switch Hardware Installation Guide |
|