Whirlpool LI3ZJB / W10331012B Tools and Parts, Prepare Internal Blower System, Tools needed

Page 3

INSTALLATION REQUIREMENTS

Tools and Parts

Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here.

Tools needed

Phillips screwdriver

Parts supplied (600 CFM models)

Remove parts from packages. Check that all parts are included.

Blower assembly

Motor support bracket

Motor spring clip

2 - 6 x 1 mm nuts

5 - 4.2 x 8 mm screws

2 - 6 x 16 mm screws

2 - 6.4 x 11 mm lock washers

T-20 Torx®† adapter

Parts supplied (1200 CFM models)

Remove parts from packages. Check that all parts are included.

Blower assembly

Motor support bracket

Motor spring clip

5 - 6 x 1 mm nuts

5 - 4.2 x 8 mm screws

5 - 6 x 16 mm screws

5 - 6.4 x 11 mm lock washers

T-20 Torx®† adapter

†®TORX is a registered trademark of Saturn Fasteners, Inc.

INSTALLATION INSTRUCTIONS

Prepare Internal Blower System

IMPORTANT: Perform steps 1-4 before mounting the range hood.

1.Remove grease filters from range hood. See the “Range Hood Care” section in the Use and Care Guide.

2.Install the motor support bracket using three 4.2 x 8 mm screws. Screw bracket to the inside top or back (alternate location on some models), toward the left side of the range hood.

3.Install motor spring clip using two 4.2 x 8 mm screws. Screw spring clip to the inside top or back (alternate location on some models) of the range hood at the proper location for the selected motor system. Slide the mounting tab of the spring clip through the slot in the panel and secure with the screws. Use the inside set of mounting holes for the single motor system. Use the outside set of mounting holes for the dual motor system.

B

A

D E

C

A. 4.2 x 8 mm screws (3) for motor support bracket

B. 4.2 x 8 mm screws (2) for motor spring clip

C. Motor support bracket

D. Motor spring clip (single motor assembly location)

E. Motor spring clip (dual motor assembly location)

3

Image 3
Contents Ventilateurs Internes Avec Débit DE 600 PI³/MIN ET Range Hood SafetyImportant Safety Instructions Parts supplied 600 CFM models Tools and PartsPrepare Internal Blower System Tools neededInstall Range Hood Blower Motor Single Blower Motor AssemblyDual Blower Motor Assembly Assistance or Service U.S.ACanada Disclaimer of Implied Warranties Limitation of Remedies Limited WarrantyItems Excluded from Warranty This limited warranty does not coverVotre sécurité et celle des autres est très importante Sécurité DE LA Hotte DE CuisinièreImportantes Instructions DE Sécurité Instructions ’INSTALLATION Outils et piècesPréparation du système de ventilation Interne Installation du moteur du ventilateur de la Hotte Ensemble à deux moteurs-ventilateursEnsemble à un seul moteur-ventilateur Pour plus d’assistance Assistance OU ServiceAu Canada Si vous avez besoin de pièces de rechangeLa présente garantie limitée ne couvre pas Garantie DES Gros Appareils Ménagers Whirlpool CorporationGarantie Limitée Articles Exclus DE LA Garantie