1.6 2K/4K TDI Camera Timing Diagram
4K TDI CameraLinkTM
Strobe Period :40 nS
LVAL Set –Up Time :20 nS
Line Period :40.96 µS
Blanking :1.8 µS
ExSync min Set – Up :650 nS
ExSync min pulse Width :1.8 µS
2K TDI CameraLinkTM
Strobe Period :40 nS
LVAL Set –Up Time :20 nS
Line Period :20.48 µS
Blanking :1.8 µS
ExSync min Set – Up :650 nS
ExSync min pulse Width :1.8 µS
Fairchild Imaging • CAM/CCD 2KCL.TDI & CAM/CCD-4KCL.TDI Line Scan Camera User’s Manual • Rev C• 11 of 30