1.62K/4K TDI Camera Timing Diagram

2K TDI CameraLinkTM

Strobe Period

:40 nS

LVAL Set –Up Time

:20 nS

Line Period

:20.48 µS

Blanking

:1.8 µS

ExSync min Set – Up

:650 nS

ExSync min pulse Width

:1.8 µS

4K TDI CameraLinkTM

Strobe Period

:40 nS

LVAL Set –Up Time

:20 nS

Line Period

:40.96 µS

Blanking

:1.8 µS

ExSync min Set – Up

:650 nS

ExSync min pulse Width

:1.8 µS

Fairchild Imaging • CAM/CCD 2KCL.TDI & CAM/CCD-4KCL.TDI Line Scan Camera User’s Manual • Rev C• 11 of 30

Page 11
Image 11
Fairchild CAM/CCD-2KCL.TDI, CAM/CCD-4KCL.TDI 2K/4K TDI Camera Timing Diagram 2K TDI CameraLinkTM, 4K TDI CameraLinkTM