Notes:

Exterior overshield is connected to the shells of the connectors on both ends.

3M part 14X26-SZLB-XXX-0LC is a complete cable assembly, including connectors.

Unused pairs should be terminated in 100 ohms at both ends of the cable.

2.3 Power Supply

The camera uses a single voltage input, normally set to 12 Volts @ 0.45 Amps typ.

Ripple and noise is required to be < 20 mV RMS.

Power is supplied through a Hirose connector.

When installing the mating connector, be sure to line up the slots. This action will assure that you will not bend any of the pins.

Hirose HR25-7TR-6P Receptacle

Pin #

Description

1

+12V

 

 

2

+12V

 

 

3

NC

 

 

4

GND

 

 

5

GND

 

 

6

NC

 

 

Fairchild Imaging • CAM/CCD 2KCL.TDI & CAM/CCD-4KCL.TDI Line Scan Camera User’s Manual • Rev C• 15 of 30