GB
Fitting the power supply cable
! Once the appliance has been installed, the power supply |
cable and the electrical socket must be easily accessible. |
L |
N
1.Open the terminal board by inserting a screwdriver into the side tabs of the cover. Use the screwdriver as a lever by pushing it down to open the cover (see diagram).
2.Install the power supply cable by loosening the cable clamp screw and the three wire contact screws
Connect the wires to the corresponding terminals: the Blue wire to the terminal marked (N), the Brown wire to the terminal marked (L) and the Yellow/Green wire
to the terminal marked (see diagram).
! The cable must not be bent or compressed. |
! The cable must be checked regularly and replaced by |
authorised technicians only (see Assistance). |
! The manufacturer declines any liability should these |
safety measures not be observed. |
APPLIANCE SPECIFICATIONS
Dimension* | width 43.5 cm | |
height 41 cm | ||
| depth 41 cm | |
|
| |
Volume* | 74 l | |
Dimension** | width 45.6 cm | |
height 41 cm | ||
| depth 41 cm | |
|
| |
Volume** | 77 l | |
|
| |
Electrical | voltage: 230 - 240 V~ 50Hz | |
maximum power absorbed | ||
connections | ||
|
3.Secure the cable by fastening the clamp screw.
4.Close the cover of the terminal board.
Connecting the supply cable to the mains
Install a standardised plug corresponding to the load indicated on the data plate (see table).
The appliance must be directly connected to the mains using an omnipolar switch with a minimum contact opening of 3
mminstalled between the appliance and the mains. The switch must be suitable for the charge indicated and must comply with current electrical regulations (the earthing wire must not be interrupted by the switch). The supply cable must be positioned so that it does not come into contact with temperatures higher than 50°C at any point (the back panel of the oven, for example).
!The installer must ensure that the correct electrical connection has been performed and that it is fully compliant with safety regulations.
Before connecting the appliance to the power supply, make sure that
•The appliance is earthed and the plug is compliant with the law.
•The socket can withstand the maximum power of the appliance, which is indicated on the data plate.
•The voltage is in the range between the values indicated on the data plate.
•The socket is compatible with the plug of the appliance.
If the socket is incompatible with the plug, ask an authorised technician to replace it. Do not use extension cords or multiple sockets.
| Directive 2002/40/EC on the label |
| of electric ovens. |
ENERGY | Standard EN 50304 |
| |
LABEL | Declared energy consumption for |
| Forced convection Class – |
| heating mode: Gratin |
This appliance conforms to the following European Economic Community directives:
2006/95/EEC dated 12/12/06 (Low Voltage) and subsequent amendments
– 2004/108/EEC dated 15/12/04 and subsequent amendments
- 93/68/EEC dated 22/07/93 and subsequent amendments
-2002/96/EC and subsequent amendments.
1275/2008 Standby/off mode
*Only for models with drawn rails.
**Only for models with wire rails.
PLEASE PHONE US TO REGISTER YOUR APPLIANCE AND ACTIVATE YOUR PARTS GUARANTEE ON 08448 24 24 24
6