REPLACING THE POWER SUPPLY CABLE
Important! This appliance must be connected to the electricity supply only by an authorised person.
To connect the supply cable:
■■ Unhook the terminal board cover by inserting a screwdriver into the two hooks “A” (fig. 5).
■■ Open the cable gland by unscrewing screw “F” (fig. 6), unscrew the terminal screws and remove the cable.
■■ The new supply cable, of suitable type and section, is connected to the terminal board following the diagram fig. 7.
■■ Close and hook again the terminal board cover.
N.B. The earth conductor must be left about 3 cm longer than the others.
VOLTAGE AND POWER CONSUMPTION
2250 W (9.78 A) |
FEEDER CABLE SECTION
TYPE H05RR-F
3 x 1,5 mm2 (*) (**)
(*)Connection possible with plug and outlet (**) Connection with wall box connection.
Figure 5
A
Figure 6
F |
Figure 7
220 - 240 V
L1 N (L2)
E
11