B&B Electronics CR-25E manual Field Balancing Instructions, Indications Problem Solution

Page 14

Installation & Operations Manual

 

 

CR-25E Cable Beam Barrier

Installation, Adjustment & Maintenance

13 of 31

1.11 Field Balancing Instructions

IMPORTANT: EVERY BARRIER IS BALANCED AT THE FACTORY BEFORE IT IS SHIPPED. IF ANY ADDITIONS OR CHANGES ARE MADE TO THE BARRIER ARM IN THE FIELD, THE BARRIER MAY REQUIRE RE-BALANCING. AN UNBALANCED ARM MAY DAMAGE THE OPERATOR.

If any additions or changes are made to the barrier, the following guidelines will help you determine what changes, if any, need to be made to the barrier balance:

1.Make the desired changes to the barrier arm.

2.Secure the tip end of the arm to prevent injury or accident.

3.Disconnect the connecting rod which runs between the upper and lower cranks, this will free the arm to be balanced.

INDICATIONS

PROBLEM

 

SOLUTION

Barrier arm tends to raise

Barrier is counterweight

1.

Counterweights can be

Requires more than 20 lbs. to

heavy.

 

removed.

keep it closed to traffic.

 

 

 

Barrier arm tends to lower

Barrier is arm heavy.

1.

Counterweights can be added.

Requires more than 20 lbs. to

 

 

 

keep it open to traffic.

 

 

 

A properly balanced barrier can be manually operated by one person pushing on the end of the counterweight mounting channel. It should require only 20 lbs. of force to manually operate the barrier. For detailed instructions on balancing the operator with weights, refer to the next page.

© 2007 B&B ARMR

WWW.BB-ARMR.COM

(800) 367-0387

Image 14
Contents Corporate Technical Support Field Service Support Made in the USAIntroduction WelcomeHow to Contact Us Corporate Technical Support Service SupportTable of Contents Housing INSTALLATION, Adjustment and MaintenanceHave been installed Operating mechanismCarefully. Consult Factory if Problem is not Found CR-25E Shut Down Instructions Necessary, refer to the enclosed installation instructionsCR-25E Start Up Instructions CR-25E Emergency Operation InstructionsFinal drive gear box Low speed housing Pillow Block BearingsLimit Switch Drive Chain Item Lubrication Replacement InstructionsConnecting Rod Ends Items11 Recommended Replacement Oils for CR-25E To remove the old assembly To mount the new assemblyMotor Replacement Instructions Main Power Switch S1 OFF Before Beginning Limit Switch Replacement InstructionsDisconnect Barrier Power by Throwing Indications Problem Solution Field Balancing InstructionsGate Arm Balancing Instructions Calculating Counterweight RequirementsCounterweight Sizes Adjusting the Barrier Movement 2007 B&B Armr 800 2007 B&B Armr 800 2007 B&B Armr 800 Specifications Motor Limit SwitchTransmission Braking MechanismCable Anchoring System Safety SWITCHES, Terminal Blocks and WiringEnergy Absorption Cables Quality AssuranceAccessories and Major Components Housing Assembly 0025-0050-AOperator Assembly 0025-0053-B Brake Assembly 0040-0023-C Limit Switch Assembly 0040-0009-F Motor Cut Sheet Installation 22’ Clear Opening System DrawingsInstallation 14’ Clear Opening Wiring Warranty

CR-25E specifications

B&B Electronics CR-25E is a robust and versatile device designed for fulfilling the needs of industrial communication systems. Characterized by its reliability and advanced functionality, the CR-25E is widely recognized in the automation and control sectors.

One of the key features of the CR-25E is its high-speed data transmission capabilities. With support for both RS-232 and RS-485 communication protocols, the device ensures seamless integration across various systems. The CR-25E operates at speeds up to 115.2 Kbps, allowing for rapid data exchange, which is crucial in applications like robotic controls, sensors, and monitoring systems.

Another standout characteristic of the CR-25E is its built-in isolation features. With 2.5 kV isolation on the serial lines, it protects the connected equipment from voltage spikes and noise, significantly enhancing the reliability of the communication link. This isolation effectiveness is particularly valuable in environments rife with electrical interference, as it ensures stable operation and long-lasting performance.

The CR-25E supports multiple power input options, including AC and DC power supplies. This flexibility enables easy integration into existing systems without the need for extensive modifications or additional components. The device also features wide input voltage ranges, thus accommodating different industrial environments and requirements.

In terms of mounting options, the CR-25E is designed with user-friendliness in mind. The compact design and DIN rail compatibility facilitate easy installation in control panels, maximizing space efficiency while maintaining accessible connectivity for maintenance or troubleshooting.

For monitoring and configuration, the CR-25E integrates effortlessly with various industrial software and applications. The device features diagnostic LEDs to provide real-time indications of operational status, simplifying troubleshooting by allowing users to quickly identify issues.

In summary, B&B Electronics CR-25E stands out due to its high-speed data transmission, robust isolation features, versatile power input capabilities, and user-friendly design. These attributes make it a preferred choice among engineers and technicians in the field of industrial communication, ensuring that systems remain efficient, reliable, and effective in demanding operational settings.