B&B Electronics CR-25E manual 2007 B&B Armr 800

Page 17

Installation & Operations Manual

 

 

CR-25E Cable Beam Barrier

Installation, Adjustment & Maintenance

16 of 31

1)Determine the direction of rotation of the cranks. In a standard installation, the cranks pivot toward the motor, and the roadway.

The limit switch cams rotate the same direction that the pivot rotates. Cam 1 is always the raise stop, Cam 2 is always the lower stop, Cam 3 generally controls the arm lights if there are any.

IMPORTANT: Always power down at the main switch before adjusting the limit switches.

2)Manually rotate the barrier into its fully open to traffic (raised) position by inserting the manual crank onto the shaft extending from the top of the motor and turning it until the barrier reaches the desired position.

Note: At fully open, the connecting rods should be parallel with the sides of the operator and with the cranks. The cranks should be pointing straight up.

3)With an allen wrench loosen the limit switch cams just enough so that they will turn, but not so much that they are loose.

4)Rotate Cam 1 until the limit switch follower just falls off of the edge of the cam. Keep the direction of rotation of the cam in mind as you set it to ensure that when the barrier rotates, the limit switch follower will move back onto the cam.

© 2007 B&B ARMR

WWW.BB-ARMR.COM

(800) 367-0387

Image 17
Contents Made in the USA Corporate Technical Support Field Service SupportWelcome IntroductionCorporate Technical Support Service Support How to Contact UsTable of Contents Have been installed INSTALLATION, Adjustment and MaintenanceHousing Operating mechanismCarefully. Consult Factory if Problem is not Found CR-25E Start Up Instructions Necessary, refer to the enclosed installation instructionsCR-25E Shut Down Instructions CR-25E Emergency Operation InstructionsPillow Block Bearings Final drive gear box Low speed housingLimit Switch Drive Chain Item Lubrication Replacement InstructionsConnecting Rod Ends Items11 Recommended Replacement Oils for CR-25E To mount the new assembly To remove the old assemblyMotor Replacement Instructions Main Power Switch S1 OFF Before Beginning Limit Switch Replacement InstructionsDisconnect Barrier Power by Throwing Field Balancing Instructions Indications Problem SolutionGate Arm Balancing Instructions Calculating Counterweight RequirementsCounterweight Sizes Adjusting the Barrier Movement 2007 B&B Armr 800 2007 B&B Armr 800 2007 B&B Armr 800 Specifications Transmission Limit SwitchMotor Braking MechanismEnergy Absorption Cables Safety SWITCHES, Terminal Blocks and WiringCable Anchoring System Quality AssuranceHousing Assembly 0025-0050-A Accessories and Major ComponentsOperator Assembly 0025-0053-B Brake Assembly 0040-0023-C Limit Switch Assembly 0040-0009-F Motor Cut Sheet System Drawings Installation 22’ Clear OpeningInstallation 14’ Clear Opening Wiring Warranty

CR-25E specifications

B&B Electronics CR-25E is a robust and versatile device designed for fulfilling the needs of industrial communication systems. Characterized by its reliability and advanced functionality, the CR-25E is widely recognized in the automation and control sectors.

One of the key features of the CR-25E is its high-speed data transmission capabilities. With support for both RS-232 and RS-485 communication protocols, the device ensures seamless integration across various systems. The CR-25E operates at speeds up to 115.2 Kbps, allowing for rapid data exchange, which is crucial in applications like robotic controls, sensors, and monitoring systems.

Another standout characteristic of the CR-25E is its built-in isolation features. With 2.5 kV isolation on the serial lines, it protects the connected equipment from voltage spikes and noise, significantly enhancing the reliability of the communication link. This isolation effectiveness is particularly valuable in environments rife with electrical interference, as it ensures stable operation and long-lasting performance.

The CR-25E supports multiple power input options, including AC and DC power supplies. This flexibility enables easy integration into existing systems without the need for extensive modifications or additional components. The device also features wide input voltage ranges, thus accommodating different industrial environments and requirements.

In terms of mounting options, the CR-25E is designed with user-friendliness in mind. The compact design and DIN rail compatibility facilitate easy installation in control panels, maximizing space efficiency while maintaining accessible connectivity for maintenance or troubleshooting.

For monitoring and configuration, the CR-25E integrates effortlessly with various industrial software and applications. The device features diagnostic LEDs to provide real-time indications of operational status, simplifying troubleshooting by allowing users to quickly identify issues.

In summary, B&B Electronics CR-25E stands out due to its high-speed data transmission, robust isolation features, versatile power input capabilities, and user-friendly design. These attributes make it a preferred choice among engineers and technicians in the field of industrial communication, ensuring that systems remain efficient, reliable, and effective in demanding operational settings.