5) Manually rotate the barrier into its fully closed to traffic position.

Note: At fully closed, the lower drive crank should have rotated through 180 degrees, and should be pointing straight down. The connecting rods should be parallel with the sides of the housing and the cranks.

6)Rotate Cam 2 until the limit switch follower just falls off of the edge of the cam. Keep the direction of rotation of the cam in mind as you set it to ensure that when the barrier rotates, the limit switch follower will move back onto the cam.

7)Re-apply power and run the barrier open and closed. If the cams require more adjustment it is important to disconnect power before moving the limit switch cams. Be sure to re-tighten the limit switch cams once they have been properly set.

NOTE: At this point in the adjustment, the crank orientation is more important than the barrier position. At the fully open and fully closed positions, the connecting rods should be parallel with the sides of the housing, and the drive cranks should point directly up or directly down.

STEP TWO: ADJUSTING THE STOPPING AND STARTING POINTS OF THE BARRIER ARM

If the starting and stopping points of the barrier arm need to be adjusted, this will be done using the connecting rods. This should only be done if the cranks and connecting rods positions are correct as described above.

© 2007 B&B ARMR

WWW.BB-ARMR.COM

(800) 367-0387

Image 18
Contents Corporate Technical Support Field Service Support Made in the USAIntroduction WelcomeHow to Contact Us Corporate Technical Support Service SupportTable of Contents Housing INSTALLATION, Adjustment and MaintenanceHave been installed Operating mechanismCarefully. Consult Factory if Problem is not Found CR-25E Shut Down Instructions Necessary, refer to the enclosed installation instructionsCR-25E Start Up Instructions CR-25E Emergency Operation InstructionsFinal drive gear box Low speed housing Pillow Block BearingsLubrication Replacement Instructions Connecting Rod Ends Items11Limit Switch Drive Chain Item Recommended Replacement Oils for CR-25E To remove the old assembly To mount the new assemblyMotor Replacement Instructions Limit Switch Replacement Instructions Disconnect Barrier Power by ThrowingMain Power Switch S1 OFF Before Beginning Indications Problem Solution Field Balancing InstructionsCalculating Counterweight Requirements Counterweight SizesGate Arm Balancing Instructions Adjusting the Barrier Movement 2007 B&B Armr 800 2007 B&B Armr 800 2007 B&B Armr 800 Specifications Motor Limit SwitchTransmission Braking MechanismCable Anchoring System Safety SWITCHES, Terminal Blocks and WiringEnergy Absorption Cables Quality AssuranceAccessories and Major Components Housing Assembly 0025-0050-AOperator Assembly 0025-0053-B Brake Assembly 0040-0023-C Limit Switch Assembly 0040-0009-F Motor Cut Sheet Installation 22’ Clear Opening System DrawingsInstallation 14’ Clear Opening Wiring Warranty

CR-25E specifications

B&B Electronics CR-25E is a robust and versatile device designed for fulfilling the needs of industrial communication systems. Characterized by its reliability and advanced functionality, the CR-25E is widely recognized in the automation and control sectors.

One of the key features of the CR-25E is its high-speed data transmission capabilities. With support for both RS-232 and RS-485 communication protocols, the device ensures seamless integration across various systems. The CR-25E operates at speeds up to 115.2 Kbps, allowing for rapid data exchange, which is crucial in applications like robotic controls, sensors, and monitoring systems.

Another standout characteristic of the CR-25E is its built-in isolation features. With 2.5 kV isolation on the serial lines, it protects the connected equipment from voltage spikes and noise, significantly enhancing the reliability of the communication link. This isolation effectiveness is particularly valuable in environments rife with electrical interference, as it ensures stable operation and long-lasting performance.

The CR-25E supports multiple power input options, including AC and DC power supplies. This flexibility enables easy integration into existing systems without the need for extensive modifications or additional components. The device also features wide input voltage ranges, thus accommodating different industrial environments and requirements.

In terms of mounting options, the CR-25E is designed with user-friendliness in mind. The compact design and DIN rail compatibility facilitate easy installation in control panels, maximizing space efficiency while maintaining accessible connectivity for maintenance or troubleshooting.

For monitoring and configuration, the CR-25E integrates effortlessly with various industrial software and applications. The device features diagnostic LEDs to provide real-time indications of operational status, simplifying troubleshooting by allowing users to quickly identify issues.

In summary, B&B Electronics CR-25E stands out due to its high-speed data transmission, robust isolation features, versatile power input capabilities, and user-friendly design. These attributes make it a preferred choice among engineers and technicians in the field of industrial communication, ensuring that systems remain efficient, reliable, and effective in demanding operational settings.