Maytag HRV-150, HRV-210 Installation of the Controls, Dimensions and Specifications Main Controls

Page 22

8.0

InstallationoftheControls

8.1DIMENSIONS AND SPECIFICATIONS (MAIN CONTROLS)

Voltage: 12 volts DC

Dimensions: 5” x 5” x 1 3/8”

(127 mm x 127 mm x 35 mm)

VC0016

13/8"

(35 mm)

5" (127 mm)

5" (127 mm)

FRONT VIEW

SIDE VIEW

8.2INSTALLATION OF THE MAIN CONTROL

(BASIC AND ELECTRONIC)

CAUTION

Never install more than one main control per unit.

INSTRUCTIONS:

1- Determine the location of the control. The wall control must be installed in a central location on the main floor. Typical locations for these controls are kitchen, main hallways and family room.

2- Remove the button(s) and the cover plate of the control.

VC0026

ELECTRONICBASIC

3- Install the wall control 60 inches (1.5 m) from the floor and leave a free space of at least 2 inches (5 cm) to the right of the control to allow user to slide out the control instructions.

Use the template provided in the control box to position the wire hole and the screw holes. Use the screws and the plastic anchors provided in the installation kit to secure the control. (See figure 16.)

2" (5 cm)

60" (1.5 m)

VD0025

figure 16

22

Image 22
Contents Installer Manual Ventilation SystemsTable of Contents About this Manual Nstallation of the C OntrolsService To Order Parts Contact your local distributor Sizing High speedHRV Technical Data ERV-210Model Number ERV-150 Model Number HRV-150 Model numbers ERV-150, HRV-150 ERV-210, HRV-210 Typical Installation Fully Ducted SystemInstallation Inspect the Contents of the BOXPlanning of the Ductwork Installation cont’dCalculating the Duct Size Installing the Ductwork and Registers Calculating the Duct Size CONT’DInstalling the Ductwork and Registers cont’d Method 1 return-supply Method 2 return-returnRigid duct Connecting Ducts to the UnitInsulated flexible duct Do not use screws to connect rigid ducts to the ports Exhaust Hood Installing the Exterior Hoods Connecting the Drain 152 mm Intake Hood 18 457 mm Optional ductOptional Control Control DevicesAll models require a main control Characteristics of cold weather TBI mode Other FeaturesSpecial Cold Weather TBI Mode for Ervs Main and Optional Controls Available for Your UnitInstallation of the Main Control Installation of the ControlsDimensions and Specifications Main Controls Never install more than one main control per unitInstallation of the Main Control cont’d Electrical Connection to Optional Controls Electrical Connection to the FurnaceWiring DiagramIf you are using Flow Measuring Stations If you are using Flow CollarsAir Flow Balancing Balancing Procedure 11.0 Overall Verification Main ControlsMaintenance / Instructions for User Do not oil the motor. It is already permanently lubricatedTroubleshooting Start-up troubleshootingLight does not stay on Warranty References