Hobart ML-124069, HQC135, ML-124070 Location, Installation with Optional Insulated Floor Panel

Page 5

Fully assembled units have the coil and fan unit, probes and controls prewired. Place assembled unit in final position ready for connection of refrigeration lines and electrical supply. Compressor unit can be located remote or self-contained (mounted on top of the cabinet with quick-connect couplings and lines in place). Alternatively, the chiller can be shipped disassembled (knocked down), requiring on- site assembly. When chillers are shipped dissassembled, lay out panels in a staging area. Lay panels on foam blocks used for packing to avoid scratches on the panels. Identify fasteners and components.

LOCATION

Allow reasonable clearance for installation of electrical and refrigeration lines above the chiller cabinet.

INSTALLATION WITH OPTIONAL INSULATED FLOOR PANEL

The chiller can be ordered with an optional 3" deep floor panel, without a floor panel or with a stainless steel sheet floor. When installed with 3" insulated floor panel, the chiller can be installed in a recessed area of the floor or with an optional ramp.

The floor panel is preferred to be installed in a recessed area so carts can roll flat into the Chiller. When installing a recessed floor, a pit must be constructed in the concrete slab at least 4 inches in depth with a 12" clearance around the perimeter. The 4 inch depth is a minimum requirement. Floor panels are 3 inches in depth, the remaining inch is used for sand to facilitate leveling (Fig.1). The interior floor of the cabinet should be even with the building floor.

INSTALLATION WITHOUT OPTIONAL INSULATED FLOOR PANEL

If no insulated floor panel is ordered, black vinyl screeds are provided. The wall panels of the chiller cabinet are inserted in the black vinyl screeds during installation (Fig. 2). The chiller should be installed on a smooth level surface. If necessary, further leveling may be provided by shimming between the floor and wall panels.

WALL PANEL

4” 3” MIN.

PL-53060

BLACK VINYL SCREED

PL-41153-1

Fig. 1

Fig. 2

INSTALLATION WITH OPTIONAL STAINLESS STEEL SHEET METAL FLOOR

The stainless steel sheet metal floor can be glued directly to the building floor before erection of the QuickChill cabinet. Mark the 40" x 50" floor area where the QuickChill will be erected.

Make sure the floor is level before proceeding. If the floor is not level the wall panels will not be vertical, the roof panels will not fit properly and the hinged door will not operate properly.

Both the building floor and the stainless steel sheet must be clean, dry and free from grease, oil, wax or other surface contaminants.

Avoid glue contact with skin or eyes. Provide adequate ventilation. Do not breathe fumes. Follow the glue manufacturer's instructions. Refer to assembly instructions shipped with the floor.

Allow at least 24 hours for the glue to set before beginning installation of the QuickChill cabinet.

– 5 –

Image 5
Contents HQC135 & HQC200 Quickchillers Table of Contents Page Uncrating GeneralLocation Installation with Optional Insulated Floor PanelInstallation Without Optional Insulated Floor Panel Left Side Right Side Coil & FAN Unit Door & Frame Ceiling Panel AssemblyAssembly Internal Electrical Connections Left Side of FigControl Cables Product Probe Assembly Temperature Control Sensors Down this Tube Temperature Control SensorsInstallation of Remote Alarm Optional Drain Line InstallationFans and Defrost Heaters Refrigeration ConnectionsElectrical Data Electrical ConnectionsCondenser Recommendations GeneralOutdoor Condensing Units Valve and Pressure SettingsPipe Sizing Guidelines Water Cooled Condensing Units Water Flow Door Switch Over TemperatureFAN Door Switch START-UPAdhesive-Backed Label Stock for Optional Label Printer When Power is Restored After a Power InterruptionPrinter Supplies Main Menu Holding If probes are utilized, they will display temperature but To adjust the Cycle Time Press ↓ or ↑Select Stop / Reset to obtain these menu items ADD 30 Minutes adds 30 minutes to the timerPage Two products displayed are the most recently Chilled products. The ↓ key will access the nextEnabled product from the product list, etc Beginning at Follow the cycle run information on pages 22Product List Timer indicates the run time. No printed reports are Temperatures are indicated for air and probesFrom the Main Menu, select More and Hold Prod AvailableProducts SetupUsers SYS PAR Clock Access the Sys Par 1 menu as shown onLogging Temps in FRemote Alarm Access the Sys Par 2 menu as shown onFrom Sys Par 2, select Alarms AlarmsChill ModeSoft Chill Editor Buzzer FAC PresetsGlossary On a PC, the screen at left displays GlossaryError Messages CleaningMaintenance Program Condenser Coil

HQC200, ML-124070, ML-124069, HQC135 specifications

Hobart, a name synonymous with quality and innovation in food preparation equipment, boasts a diverse line of products designed for the industrial kitchen. Among their offerings are the HQC135, ML-124069, ML-124070, and HQC200, each engineered to meet the demanding needs of a commercial kitchen.

The HQC135 is a dynamic countertop food processor that excels in versatility and efficiency. Designed for both small and large-scale operations, it features a powerful motor capable of handling various food items, from fresh vegetables to nuts and meats. Its precision cutting blades are crafted from high-quality stainless steel, ensuring durability and optimal performance. The intuitive control panel allows users to adjust settings for speed and time, making it facile to achieve the desired texture and consistency.

Next, the ML-124069 and ML-124070 are collaborative models specializing in food storage solutions. These models are characterized by their robust construction, designed to withstand the rigors of daily use in commercial kitchens. Both models come equipped with advanced temperature control systems, ensuring that perishable goods are maintained at optimal conditions. Their user-friendly interfaces include digital displays that provide real-time monitoring, allowing chefs to manage inventory efficiently and safely.

The HQC200 stands out in Hobart's lineup as an exemplary mixer with high-capacity capabilities suited for large batch production. This model integrates cutting-edge technology, including a planetary mixing mechanism that ensures thorough mixing and blending of ingredients. Its ergonomic design includes a tilt-back head for easy access to the mixing bowl and a variety of available attachments to accommodate different mixing requirements—from kneading dough to whipping cream. The HQC200 is also equipped with a safety interlock system, ensuring safe operation at all times.

Collectively, these models reflect Hobart's commitment to quality, innovation, and ease of use, making them essential components for any commercial kitchen. The emphasis on user-friendly interfaces, advanced technology, and superior materials not only enhances efficiency but also delivers excellent results, meeting the rigorous demands of food service professionals. Whether you require food processing, storage, or mixing solutions, Hobart's range provides the functionality and reliability that helps to elevate culinary operations to new heights.