Nuvo NV-E6DXS Installing Essentia in Your Home, Complete Crimping Instructions for Cat-5 Fig

Page 12

Installing Essentia in Your Home

I.Complete Crimping Instructions for Cat-5 (Fig. 1)

The NuVo audio systems require Cat-5, unshielded, twisted pair (UTP), for communication between the keypads and the main amplifier unit. Each end of the wire is terminated with an RJ45 connector.

The correct wiring scheme for the Cat-5 wire is stan- dard EIA/TIA 568A, which is the industry standard for computer networking. Properly terminating the Cat-5 wire is crucial for the operation of the system. It is very important to use a good quality crimp tool, and testing each termination with a Cat-5 wire tester will insure that your system operates flawlessly.

Step-by-Step Crimping Instructions

1.Strip a 2 to 3 inch portion of the insulation, expos- ing the 4 twisted pairs.

2.Untwist the wires and fan them out individually. Arrange the wires into the correct color scheme. Note that each of the wires is either a solid color, or a white wire with a colored stripe. The colors are green, orange, blue, and brown. The colors need to be in the order shown in Fig. 1.

3.Flatten the wires in their correct order, and trim them evenly across the top. Most crimp tools have a wire trimmer built-in. It is best to trim the wires to about 1/2" in length.

4.While holding the wires flat between your thumb and forefinger, insert the wires into the RJ45 con- nector, so each wire is in its own slot. Push the wire into the RJ45, so all 8 conductors touch the end of the connector. The insulation jacket should extend beyond the crimp point of the RJ45.

5.Insert the RJ45 into the crimp tool receptacle and squeeze the tool firmly. Note that a ratchet type tool should tighten down until it no longer clicks.

6.The RJ45 should be firmly crimped to the Cat-5 insu- lation. It is necessary that the color scheme be repeated identically on each end of the wire.

 

 

 

 

 

-

 

Bus

+

 

 

 

 

 

 

Data

Bus

Data

 

 

 

 

 

Ground

Serial

Serial

 

Signal Ground

Plus

12V

 

 

 

 

IR

 

1

2

3

4

5

6

 

7

8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pair 2

 

Pair 1

 

Pair 4

 

 

 

 

 

 

 

 

 

 

Pair 3

Fig. 1: CAT-5 568A wiring scheme

Pin #

1.Green Stripe

2.Green

3.Orange Stripe

4.Blue

5.Blue Stripe

6.Orange

7.Brown Stripe

8.Brown

Note: Colors listed as “Stripe” are a white wire with a col- ored stripe. In other words, Orange Stripe is a white wire with orange stripes.

Step 1

Step 2

Step 3

Step 4

Step 5

Step 6

12

Image 12
Contents Essentia English French Essentia IntroductionEssentia D Wiring Diagram Quick Start Guide StepStep Amplifier Front Panel Amplifier Back Panel Keypad RC2 Remote Control Installing Essentia in Your Home Complete Crimping Instructions for Cat-5 FigII. Installing the Essentia Amplifier III. Installing the NV-E6DEZP EZ Port FigIV. Connecting the EZ Port to Essentia amplifier FigEssentia Network Connection Network CableVI. Connecting the IR Emitters VII. Expanding Essentia to 12 ZonesVIII. Installing the Essentia keypads Keypad DIP switch chartIX. Setting the Zone Address DIP Switches Fig Additional Zone Keypads FigXI. Source Grouping Fig XII. Volume Reset Fig XIII. Parental LockXIV. Changing the Buttons on Essentia Keypad Fig NV-RC2 Remote Learning RemoteEssentia Accessories NV-MI1 Mute Interface Adapter FigAccessories NV-LSI12 Local Source Interrupt FigNV-P2100 200 Watt Auxiliary Amplifier Fig NV-P2100 AmplifierEssentia Amplifier RS232 InterfaceTroubleshooting SymptomRemedy Essentia Specifications WarrantyResponse #IRSETaa,bb,cc,dd,ee,ffCR where Response # Allmoncr USE Lead 0 in Tens Place for Value Less than Response #ZxxLKONCR Page Delhi Pike Cincinnati, OH 45238 U.S.A