Once it is SET by one of these commands:

a. It will remain set until power is cycled on the unit.

b. Non-address DIP switch changes on a connected KEYPAD connected to this zone will be ignored.

If override state is "0", this response is also issued whenever non-address KEYPAD DIP switches are changed.

*********************************************************************************

COMMAND:

*ZxxON<CR> – Turn zone xx ON.

RESPONSE:

Same response as for *ZxxCONSR<CR>

*********************************************************************************

COMMAND:

*ZxxOFF<CR> – Turn zone xx OFF.

RESPONSE:

Same response as for *ZxxCONSR<CR>

*********************************************************************************

COMMAND: *ALLOFF<CR> – Turn ALL zones OFF.

RESPONSE: #ALLOFF<CR>

This RESPONSE is also issued when ALL OFF is pressed on any KEYPAD.

*********************************************************************************

COMMAND: *ALLV+<CR> – Ramp ALL zones UP at a 10 dB/second rate in 1 dB steps.

RESPONSE: #ALLV+<CR>

The ramp action will be cancelled when all zones reach MAXIMUM volume, or when an *ALLHLD<CR> Command is received. Note that to stop the ramp with this command before maximum volume, one reference zone must be periodically polled with a *ZxxCONSR<CR> Command to determine when the desired volume point has been reached. Note that ramps in different zones may start at different levels and will all ramp at the same rate.

*********************************************************************************

COMMAND: *ALLV-<CR>– Ramp ALL zones DOWN at a 10 dB/second rate in 1 dB steps.

RESPONSE: #ALLV-<CR>

The ramp action will be cancelled when all zones reach MINIMUM (OFF) volume, or when an *ALLHLD<CR> Command is received. Note that to stop the ramp with this command before the minimum volume, one reference zone must be periodically polled with a *ZxxCONSR<CR> Command to determine when the desired volume point has been reached. Note that ramps in different zones may start at different levels and will all ramp at the same rate.

*********************************************************************************

COMMAND: *ALLHLD<CR> – Stops ramp action initiated by *ALLV+<CR> Or *ALLV-<CR>

RESPONSE: #ALLHLD-<CR>

This results in a HOLD of the level at time of command receipt.

*********************************************************************************

COMMAND:

*ALLMON<CR> – ALL MUTE ON.

RESPONSE:

# ALLMON<CR>

*********************************************************************************

COMMAND: *ALLMOFF<CR> – ALL MUTE OFF.

RESPONSE: #ALLMOFF<CR>

********************************************************************************

COMMAND:

*ZxxSRCp<CR> – Switch zone xx to SOURCE p ( 1 to 6).

RESPONSE:

Same response as for *ZxxCONSR<CR>

*********************************************************************************

28

Image 28
Contents Essentia English French Essentia IntroductionEssentia D Wiring Diagram Quick Start Guide StepStep Amplifier Front Panel Amplifier Back Panel Keypad RC2 Remote Control Installing Essentia in Your Home Complete Crimping Instructions for Cat-5 FigII. Installing the Essentia Amplifier III. Installing the NV-E6DEZP EZ Port FigIV. Connecting the EZ Port to Essentia amplifier FigEssentia Network Connection Network CableVI. Connecting the IR Emitters VII. Expanding Essentia to 12 ZonesVIII. Installing the Essentia keypads Keypad DIP switch chartIX. Setting the Zone Address DIP Switches Fig Additional Zone Keypads FigXI. Source Grouping Fig XII. Volume Reset Fig XIII. Parental LockXIV. Changing the Buttons on Essentia Keypad Fig NV-RC2 Remote Learning RemoteEssentia Accessories NV-MI1 Mute Interface Adapter FigAccessories NV-LSI12 Local Source Interrupt FigNV-P2100 200 Watt Auxiliary Amplifier Fig NV-P2100 AmplifierEssentia Amplifier RS232 InterfaceSymptom TroubleshootingRemedy Essentia Specifications WarrantyResponse #IRSETaa,bb,cc,dd,ee,ffCR where Response # Allmoncr USE Lead 0 in Tens Place for Value Less than Response #ZxxLKONCR Page Delhi Pike Cincinnati, OH 45238 U.S.A