Nuvo NV-E6DXS, NV-E6DMS owner manual Response #ZxxLKONCR

Page 30

*********************************************************************************

COMMAND:

*ZxxVRSTON<CR> – zone xx VOLUME RESET ON.

RESPONSE:

Same response as for *ZxxSETSR<CR>

NOTE: sending this command to the E6D will set override (lock out KEYPAD non-address DIP switches) for this zone until power is cycled.

*********************************************************************************

COMMAND:

*ZxxVRSTOFF<CR> – zone xx VOLUME RESET OFF.

RESPONSE:

Same response as for *ZxxSETSR<CR>

NOTE: sending this command to the E6D will set override (lock out KEYPAD non-address DIP switches) for this zone until power is cycled.

*********************************************************************************

COMMAND: *ZxxLKON<CR> – zone xx KEYPAD LOCK ON – This will INHIBIT ANY keypad control input on the zone.

This is the same as activating the Parental lock control at a keypad by holding down a SOURCE key for three seconds).

RESPONSE: #ZxxLKON<CR>

*********************************************************************************

COMMAND: *ZxxLKOFF<CR> – zone xx KEYPAD LOCK ON – This will RESTORE ALL keypad control input on the zone (useful as Parental lock control) . This is the same as de-activating the Parental lock control at a keypad by holding down a SOURCE key for three seconds).

RESPONSE: #ZxxLKOFF<CR>

*********************************************************************************

COMMAND: *VER<CR> – Firmware version query.

RESPONSE: #NUVO_E6D_vx.yy<CR> where x is the major version number and yy is the minor version number.

*********************************************************************************

RESPONSE: #EXTMON<CR> Issued whenever the External MUTE first activates (closure to ground) and 0 whenever the External MUTE de-activates (open connection to ground).

NOTE – there is no COMMAND associated with this response; it is always initiated by a change at the EXT. MUTE input.

*********************************************************************************

RESPONSE: #EXTMOFF<CR> Issued whenever External MUTE de-activates (open connection to ground).

NOTE – there is no COMMAND associated with this response; it is always initiated by a change at the EXT. MUTE input.

30

Image 30
Contents Essentia English French Essentia IntroductionEssentia D Wiring Diagram Quick Start Guide StepStep Amplifier Front Panel Amplifier Back Panel Keypad RC2 Remote Control Installing Essentia in Your Home Complete Crimping Instructions for Cat-5 FigII. Installing the Essentia Amplifier III. Installing the NV-E6DEZP EZ Port FigEssentia Network Connection IV. Connecting the EZ Port toEssentia amplifier Fig Network CableVI. Connecting the IR Emitters VII. Expanding Essentia to 12 ZonesVIII. Installing the Essentia keypads Keypad DIP switch chartIX. Setting the Zone Address DIP Switches Fig Additional Zone Keypads FigXI. Source Grouping Fig XII. Volume Reset Fig XIII. Parental LockXIV. Changing the Buttons on Essentia Keypad Fig NV-RC2 Remote Learning RemoteEssentia Accessories NV-MI1 Mute Interface Adapter FigAccessories NV-LSI12 Local Source Interrupt FigEssentia Amplifier NV-P2100 200 Watt Auxiliary Amplifier FigNV-P2100 Amplifier RS232 InterfaceTroubleshooting SymptomRemedy Essentia Specifications WarrantyResponse #IRSETaa,bb,cc,dd,ee,ffCR where Response # Allmoncr USE Lead 0 in Tens Place for Value Less than Response #ZxxLKONCR Page Delhi Pike Cincinnati, OH 45238 U.S.A