Nuvo NV-E6DMS IX. Setting the Zone Address DIP Switches Fig, Additional Zone Keypads Fig

Page 17

IX. Setting the Zone Address DIP

Switches (Fig. 8)

The first four switches on the keypads are designed to create a specific binary address identifying each zone to the amplifier. Setting each zone address is easy, but it is important to note that each keypad must have its own unique setting.

Each switch can either be placed in an up or down posi- tion. The chart on each keypad indicates the switch position using a "1" for the switch in its down position, and "0" for the switch in its up position. Thus, the set- ting for Zone 1 is 1000, or switch #1 in the down posi- tion and switches #2-4 in the up position.

Once each keypad is set for its zone, you should be able to control volume, change the source selection, and turn the zone on or off. The corresponding zone LED

Fig. 8: Keypad Zone Address Switch Settings

Zone 1

 

 

 

 

Zone 2

 

 

 

 

 

 

 

UP

0

ON

 

 

 

UP

0

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DOWN

1

1

2

3

4 5 6 7 8

9

DOWN

1

1 2

3

4

5

6

7

8

9

Switch 1 down Switches 2-4 up

Switch 1 up Switch 2 down

 

 

 

 

 

 

 

Switches 3&4 up

 

 

 

 

Zone 3

 

 

 

 

Zone 4

 

 

 

 

 

 

 

UP

0

ON

 

 

 

 

UP

0

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DOWN

1

1

2

3

4 5 6 7 8

9

DOWN

1

1 2

3

4

5

6

7

8

9

Switches 1&2 down Switches 3&4 up

Switch 1&2 up Switch 3 down

 

 

 

 

 

 

 

Switches 4 up

 

 

 

 

 

 

Zone 5

 

 

 

 

Zone 6

 

 

 

 

 

 

 

UP

0

ON

 

 

 

UP

0

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DOWN

1

1

2

3

4 5 6 7 8

9

DOWN

1

1 2

3

4

5

6

7

8

9

Switch 1 down Switch 2 up

 

Switch 1 up Switches 2&3 down

Switch 3 down Switch 4 up

Switch 4 up

 

 

 

 

 

 

 

on the face of the amplifier will turn on when the zone keypad is turned on.

Zone 7

Zone 8

UP 0

ON

UP 0

ON

DOWN

1

1

2

3

4

5

6

7

8

9

Switches 1-3 down Switch 4 up

Zone 9

DOWN

1

1

2

3

4

5

6

7

8

9

Switches 1-3 up Switches 4 down

Zone 10

UP 0

ON

UP 0

ON

DOWN

1

1

2

3

4

5

6

7

8

9

Switch 1 down Switches 2&3 up Switch 4 down

Zone 11

DOWN

1

1

2

3

4

5

6

7

8

9

Switch 1 up Switch 2 down Switches 3 up Switch 4 down

Zone 12

UP 0

ON

UP 0

ON

DOWN

1

1

2

3

4

5

6

7

8

9

Switches 1&2 down Switches 3 up Switch 4 down

DOWN 1

1

2

3

4

5

6

7

8

9

Switch 1&2 up Switch 3&4 down

Additional Zone Keypads (Fig. 9)

The four additional addresses labeled 1B,2B,3B, and 4B are used in zones 1-4 for an additional keypad in each of those zones.

Fig. 9: Keypad Zone Address Switch Settings

Zone 1B

 

 

 

 

Zone 2B

 

 

UP

0

ON

 

 

 

 

UP

0

ON

 

 

 

 

 

 

 

 

 

 

DOWN

1

1

2

3

4 5 6 7 8

9

DOWN

1

1 2

3

4 5 6 7 8 9

Switch 1 down Switch 2 up

 

Switch 1 up Switches 2-4 down

Switch 3&4

 

 

 

 

 

 

 

 

Zone 3B

 

 

 

 

 

 

Zone 4B

 

 

 

 

 

 

 

UP

0

ON

 

 

 

 

 

 

UP

0

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DOWN

1

1 2

3

4 5

6

7

8

9

DOWN

1

1 2

3

4

5

6

7

8

9

Switches 1-4 down

 

 

 

 

Switches 1-4 up

 

 

 

 

 

17

Image 17
Contents Essentia English French Introduction EssentiaEssentia D Wiring Diagram Step Quick Start GuideStep Amplifier Front Panel Amplifier Back Panel Keypad RC2 Remote Control Complete Crimping Instructions for Cat-5 Fig Installing Essentia in Your HomeIII. Installing the NV-E6DEZP EZ Port Fig II. Installing the Essentia AmplifierEssentia amplifier Fig IV. Connecting the EZ Port toEssentia Network Connection Network CableVII. Expanding Essentia to 12 Zones VI. Connecting the IR EmittersKeypad DIP switch chart VIII. Installing the Essentia keypadsAdditional Zone Keypads Fig IX. Setting the Zone Address DIP Switches FigXI. Source Grouping Fig XIII. Parental Lock XII. Volume Reset FigNV-RC2 Remote Learning Remote XIV. Changing the Buttons on Essentia Keypad FigNV-MI1 Mute Interface Adapter Fig Essentia AccessoriesNV-LSI12 Local Source Interrupt Fig AccessoriesNV-P2100 Amplifier NV-P2100 200 Watt Auxiliary Amplifier FigEssentia Amplifier RS232 InterfaceRemedy TroubleshootingSymptom Warranty Essentia SpecificationsResponse #IRSETaa,bb,cc,dd,ee,ffCR where Response # Allmoncr USE Lead 0 in Tens Place for Value Less than Response #ZxxLKONCR Page Delhi Pike Cincinnati, OH 45238 U.S.A