Hobart ML-126832, ML-126831, 3HFD140 Electrical Connections, Before First USE, Cleaning, Seasoning

Page 4

ELECTRICAL CONNECTIONS

WARNING: ELECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY WITH THE APPLICABLE PORTIONS OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER LOCAL ELECTRICAL CODES.

WARNING: DISCONNECT ELECTRICAL POWER SUPPLIES AND PLACE A TAG AT THE DISCONNECT SWITCHES TO INDICATE THAT YOU ARE WORKING ON THE CIRCUITS.

WARNING: APPLIANCES EQUIPPED WITH POWER SUPPLY CORDS AND PLUGS MUST BE CONNECTED TO PROPERLY GROUNDED MATING RECEPTACLES. IF THE RECEPTACLES ARE NOT THE PROPER GROUNDING TYPES, CONTACT AN ELECTRICIAN. DO NOT REMOVE THE GROUNDING PRONG FROM THE PLUGS.

Refer to the wiring diagram located inside each fryer front door.

ELECTRICAL DATA

 

Fry Tank

 

 

Minimum Circuit Ampacity

Model

Capacity

Volts / Hertz / Phase

Circuit Type

Maximum Protective Device

 

(lb.)

 

 

AMPS

 

 

 

 

 

 

 

120 / 60 / 1

Controls & Pump

15

 

85

208 / 60 / 3

24 KW Heaters

80

 

 

 

 

 

120 / 60 / 1

Controls & Pump

15

 

 

3HFD140

 

480 / 60 / 3

24 KW Heaters

35

 

 

 

 

 

120 / 60 / 1

Controls

15

 

 

 

140

208 / 60 / 3

30 KW Heaters

125

 

 

 

 

 

120 / 60 / 1

Controls

15

 

 

 

 

480 / 60 / 3

36 KW Heaters

50

 

 

 

 

 

 

 

120 / 60 / 1

Controls & Pump

15

 

85

208 / 60 / 3

24 KW Heaters

80

 

 

 

 

 

120 / 60 / 1

Controls & Pump

15

 

 

 

 

480 / 60 / 3

24 KW Heaters

35

 

 

 

 

 

 

 

120 / 60 / 1

Controls

15

4HFD140

140

208 / 60 / 3

30 KW Heaters

125

 

 

 

120 / 60 / 1

Controls

15

 

 

 

 

480 / 60 / 3

36 KW Heaters

50

 

 

 

 

 

 

 

120 / 60 / 1

Controls

15

 

140

208 / 60 / 3

30 KW Heaters

125

 

 

 

 

 

120 / 60 / 1

Controls

15

 

 

 

 

480 / 60 / 3

36 KW Heaters

50

 

 

 

 

 

Compiled in accordance with the National Electrical Code, NFPA-70 (latest edition).

BEFORE FIRST USE

Cleaning

Clean the fryer thoroughly, following the procedures described under CLEANING — WEEKLY OR AS REQUIRED. Clean all fryer accessories. Rinse all parts thoroughly after cleaning and wipe dry.

Seasoning

Light seasoning of the backsplash area is required to avoid possible surface corrosion. With a soft, lint-free cloth, apply a thin layer of cooking oil over the entire backsplash area. This should be done after every cleaning.

– 4 –

Image 4
Contents Electric Fryers Model 3HFD140 Electric Fryer Installation Installation Codes and StandardsGeneral UnpackingCleaning Electrical ConnectionsBefore First USE SeasoningOperation Controls FigShortening Maintenance Adding ShorteningMelt Cycle Empty the Frymate Drain PANUsing the Filter System Drain Opening Suction Opening LIDPeriodic Batch Cleaning of the Filter Tank Cleaning the Filter System Flushing and Discarding Used OilCleaning Weekly or AS Required Cleaning DailyFry Tank, Heating Elements, and Thermostat Bulb Precautions Stainless SteelFingerprints Burned On Foods and GreaseMaintenance Calibration ProceduresService Lubrication