Hobart 4HFD140, ML-126832, ML-126831 Using the Filter System, Drain Opening Suction Opening LID

Page 7

USING THE FILTER SYSTEM

Filter system parts must be in their proper positions while the system is in use . . .

Crumb Basket hangs on left Tank Handle (Fig. 4) to catch crumbs during draining.

Filter must be flat on tank bottom and Filter Orifice must be placed over the tank hole (Fig. 4).

Elbow must be threaded into Tank Fitting (Fig. 4).

Lid must be in place over tank. Drain Opening is over Crumb Basket. Elbow extends above Suction Opening.

Drawer is closed so Suction Connector on Elbow is connected to the Suction Port.

NOTE: Make sure the two O-rings are always in place inside the Suction Port.

DRAIN OPENING

SUCTION OPENING

LID

LEFT TANK HANDLE

CRUMB BASKET

 

TANK

FILTER

 

 

 

 

 

FILTER ORIFICE UNDERNEATH

SUCTION CONNECTOR

ELBOW

TANK FITTING

Fig. 4

PL-41522-1

– 7 –

Image 7
Contents Electric Fryers Model 3HFD140 Electric Fryer Unpacking InstallationInstallation Codes and Standards GeneralSeasoning CleaningElectrical Connections Before First USEControls Fig OperationEmpty the Frymate Drain PAN Shortening MaintenanceAdding Shortening Melt CycleDrain Opening Suction Opening LID Using the Filter SystemPeriodic Batch Cleaning of the Filter Tank Flushing and Discarding Used Oil Cleaning the Filter SystemCleaning Weekly or AS Required Cleaning DailyFry Tank, Heating Elements, and Thermostat Bulb Burned On Foods and Grease PrecautionsStainless Steel FingerprintsLubrication MaintenanceCalibration Procedures Service