5.If the burner manifold pressure does not meet the specifications in the tables in Step 4, unscrew the slotted cap from the top of the gas valve regulator (adjacent to the gas valve vent tube) and turn the adjusting screw to obtain the correct pressure. Turn the screw clockwise to increase pressure, counter-clockwise to decrease pressure.

6.After adjusting the manifold pressure to the correct value, reinstall the regulator cap and turn the gas valve knob to the OFF position.

7.Remove the manometer or pressure gauge fitting from the pressure tap hole and reinstall the pipe plug.

8.Place the gas valve in the PILOT position and check for gas leaks. If no leaks are found, re-light the pilot and return the unit to operation.

4.4Operator Troubleshooting

The tables that follow provide operators with a list of possible malfunctions, the probable causes of the malfunctions, and the corrective actions to take to correct the problem.

In some cases the operator may not be able to correct the problem, but will at least be able to accurately diagnose the problem, and that will assist a qualified service technician in restoring the equipment to full operation in the shortest possible time.

4-4

Image 22
Contents Hour Service Hotline Canada Page Table of Contents Parts Ordering and Service Information General InformationSafety Information Installation, Operating, and Service Personnel DefinitionsShipping Damage Claim Procedure What to do if your equipment arrives damagedInstallation Instructions General Installation RequirementsCaster/Leg Installation National Code RequirementsConnection to Gas Line Page Page Operating the Gas Valve Lighting the Pilot and BurnerPage Shutting the Fryer Down Thermostat OperationPage Page Daily Checks and Services Quarterly Checks and ServicesClean Gas Valve Vent Tube Clean Detachable Parts and AccessoriesCheck Thermostat Calibration Semi-Annual Checks and Service Check Burner Manifold PressureOperator Troubleshooting Not light all Burner does not light at allBurner does Way aroundExperiences DelayedBurner IgnitionPilot remains lit When gas valveWhen released Knob is pushedService Hotline