Frymaster GF14 Pilot remains lit, When gas valve, Knob is pushed, In, but goes out, When released

Page 25

 

Problem

 

 

Probable Cause

 

 

 

 

 

 

 

 

A.

Loose, dirty or corroded hi-limit

 

Pilot remains lit

 

 

wires.

 

when gas valve

 

B.

If the above does not correct the

 

knob is pushed

 

 

problem, the probable causes are a

 

in, but goes out

 

 

weak gas valve pilot magnet, pilot

 

when released.

 

 

generator low millivolt output, or

 

 

 

 

a high-limit thermostat stuck open.

 

Thermostat

 

A. Thermostat out of calibration.

 

 

 

 

 

does not control

 

 

 

 

at set point.

 

 

 

 

 

B. Failed thermostat.

 

 

 

 

 

 

 

 

Corrective Action

A.Clean/tighten hi-limit wires on gas valve.

B.Call FASC.

A.Check calibration of thermostat in accordance with procedures in Section 4.2 of this manual.

B.Call FASC.

4-7

Image 25
Contents Hour Service Hotline Canada Page Table of Contents General Information Parts Ordering and Service InformationSafety Information Definitions Installation, Operating, and Service PersonnelWhat to do if your equipment arrives damaged Shipping Damage Claim ProcedureGeneral Installation Requirements Installation InstructionsNational Code Requirements Caster/Leg InstallationConnection to Gas Line Page Page Lighting the Pilot and Burner Operating the Gas ValvePage Thermostat Operation Shutting the Fryer DownPage Page Quarterly Checks and Services Daily Checks and ServicesClean Gas Valve Vent Tube Clean Detachable Parts and AccessoriesCheck Thermostat Calibration Check Burner Manifold Pressure Semi-Annual Checks and ServiceOperator Troubleshooting Burner does Burner does not light at allNot light all Way aroundBurner DelayedExperiences IgnitionWhen released When gas valvePilot remains lit Knob is pushedService Hotline