Frymaster FPHD65 operation manual Optional Filter Hose and Wand Operation

Page 45

SUFF/UFF FILTRATION SYSTEMS

CHAPTER 6: INSTALLATION AND OPERATION

6.4.3 Optional Filter Hose and Wand Operation

Some frying systems come equipped with an optional filter hose, wand, and toggle switch to facilitate the removal of debris from the frypot. The hose attaches to a no quick-disconnect on the bottom front of the fryer and is controlled using a toggle switch on the fryer control panel.

1.Ensure the oil is at operating temperature (~350°F/~177°C). Turn the fryer off and open the fryer drain valve. Allow the oil to drain into the filter pan.

Moving the red drain valve handle to open the drain valve, allowing hot oil to drain into the filter pan.

2.When all the oil has drained from the frypot, connect the hose/wand assembly to the quick- disconnect on the front bottom of the fryer cabinet. Ensure the hose is properly connected before proceeding.

3.Place the wand into the open frypot and activate the filter with the wand/disposal switch (rocker switch) on the front of the cabinet.

DO NOT PROCEED UNLESS THE WAND IS INSIDE THE FRYPOT. Hot oil can immediately flow from the wand when it is attached, causing burns if the wand is not in the frypot.

Optional hose/wand disconnect properly connected to disconnect valve in fryer cabinet.

After the wand end is properly positioned inside the appropriate frypot, activate the filter pump with the wand/ disposal switch located on the front of the fryer.

6-15

Image 45
Contents HD Models Series Gas Fryers Hour Service HotlineCanada Page High Efficiency Decathlon HD Series Gas Fryers Table of ContentsTable of Contents Applicability and Validity After PurchaseOrdering Parts Service Information Safety InformationComputer Information Qualified and/or Authorized Operating Personnel Service PersonnelGeneral Receiving and Unpacking EquipmentPrinciples of Operation Product DescriptionRating Plate Pre-installationAir Supply and Ventilation Installation StandardsEquipment Installed at High Altitudes Leveling the Fryer Fryers equipped with legs only Installing the FryerRear Only Front Only Installing Casters and LegsNational Code Requirements Gas ConnectionsGas Supply Type and Pressure Gas Connections NON-CE Altitudes of 2000 feet or less Gas SpecificationsCE only Altitudes of 2000 feet or less Gas Conversion ProceduresElectrical Connections Initial Start-up Pilot Lighting Procedures, Standing Pilot Only Boil-Out Procedure Boil-Out Procedure Final Preparation Final Preparation Operating Instructions Electronic Thermostat Controller Electronic Thermostat Controller/Computer When in useElectronic Thermostat Controller/Computer High Efficiency Decathlon HD Series GAS Fryers Filtration Filter Unit Types Filter PreparationFilter Leaf Assembling the Filter Crumb screen properly placed Handle Applying filter powder to filter-leaf Installing the Filter Filtering Tools Pan Preparation and Operation Operating the FilterMove the red drain valve handle into the open position Filter Operation SUFF/UFF Filtration Systems Installation and Operation Do not Allow Crumbs to Accumulate in Tray Optional Filter Hose and Wand Operation Hose and Wand Operation Complete FilteringWeekly DailySee filtration manual for filtration maintenance procedures Periodic/ AnnualStainless Steel Care Pilot Burner Malfunction Main Burner Malfunctions Electronic Thermostat Controller Calibration Service Hotline