HIGH EFFICIENCY DECATHLON (HD) SERIES GAS FRYERS
CHAPTER 3: INSTALLATION
3.5 Gas Connections (cont.)
WARNING
Do not attach accessories to this fryer unless fryer is secured from tipping. Personal
injury may result.
2.The fryer must be restrained by means independent of the flexible coupling or connector in order to limit the movement of the fryer. Restraining brackets are located on the back panel of the fryer for the attachment of restraints.
3.If disconnection of the restraint is necessary, this restraint must be reconnected after the fryer has been returned to its originally installed position.
I.After
AUSTRALIAN REQUIREMENTS
To be installed in accordance with AS 5601 / AG 601, local authority, gas, electricity, and any other relevant statutory regulations.
3.5 Gas Specifications
NON-CE (Altitudes of 2000 feet or less)
MODEL | INPUT | GAS | ORIFICE | ORIFICE | QTY | EQUIPMENT | ||
PRESSURE | ||||||||
(BTU) | TYPE | (MM) | PART NO. | |||||
|
| MBAR | INCH W.C. | |||||
|
|
|
|
|
| |||
D20G | 50 | NAT | 2.18(#44) | 2 | 10 | 4 | ||
LP | 1.40(#54) | 2 | 27.5 | 11 | ||||
|
| |||||||
|
|
|
|
|
|
|
| |
D50G | 85 | NAT | 2.08(#45) | 4 | 10 | 4 | ||
LP | 1.32(#55) | 4 | 27.5 | 11 | ||||
|
| |||||||
|
|
|
|
|
|
|
| |
D50G(HP) | 120 | NAT | 2.53(#39) | 4 | 10 | 4 | ||
LP | 1.51(#53) | 4 | 27.5 | 11 | ||||
|
| |||||||
|
|
|
|
|
|
|
| |
D50GDDHP | 115 | NAT | 2.44(#41) | 4 | 10 | 4 | ||
LP | 1.51(#53) | 4 | 27.5 | 11 | ||||
|
| |||||||
|
|
|
|
|
|
|
| |
D60G | 112 | NAT | 2.08(#45) | 5 | 10 | 4 | ||
LP | 1.32(#55) | 5 | 27.5 | 11 | ||||
|
| |||||||
|
|
|
|
|
|
|
| |
D60G(HP) | 150 | NAT | 2.53(#39) | 5 | 10 | 4 | ||
LP | 1.51(#53) | 5 | 27.5 | 11 | ||||
|
| |||||||
|
|
|
|
|
|
|
| |
D80G | 122 | NAT | 2.26(#43) | 5 | 10 | 4 | ||
LP | 1.40(#54) | 5 | 27.5 | 11 | ||||
|
| |||||||
|
|
|
|
|
|
|
| |
D80G(HP) | 165 | NAT | 2.58(#38) | 5 | 10 | 4 | ||
LP | 1.61(#52) | 5 | 27.5 | 11 | ||||
|
| |||||||
|
|
|
|
|
|
|
| |
HD50G | 95 | NAT | 2.26(#43) | 4 | 10 | 4 | ||
LP | 1.40(#54) | 4 | 27.5 | 10 | ||||
|
| |||||||
|
|
|
|
|
|
|
| |
HD60G | 125 | NAT | 2.26(#43) | 5 | 10 | 4 | ||
LP | 1.40(#54) | 5 | 27.5 | 10 | ||||
|
| |||||||
|
|
|
|
|
|
|
|
NOTE: Outlet gas pressure must be adjusted strictly within the above requirements 5 to 10 minutes after the appliance is operating.
(Pilot Flame Adjustment: Turn the pilot adjustment screw