HIGH EFFICIENCY DECATHLON (HD) SERIES GAS FRYERS
CHAPTER 8: TROUBLESHOOTING
DANGER
Hot shortening will cause severe burns. Never attempt to move this appliance when filled with hot shortening or to transfer hot shortening from one container to another.
DANGER
This equipment should be unplugged when servicing, except when electrical circuit
tests are required. Use extreme care when performing such tests.
This appliance may have more than one electrical power supply connection point.
Disconnect all power cords before servicing.
Inspection, testing and repair of electrical components should be performed by an
authorized service agent only.
The problems and possible solutions covered are those most commonly encountered. To troubleshoot, perform the test
8.1Pilot Burner Malfunction
A.Pilot will not ignite; no evidence of gas at pilot burner.
1.Check that gas valve is open and gas is present at the gas valve.
2.Check pilot burner orifice for dirt or lint.
3.Authorized Service Agent Only: Remove pilot burner
B.Pilot burner ignites but will not remain lit when gas valve manual knob is released.
1.Check that thermocouple lead is properly screwed into thermocouple connection bushing on gas valve.
2.Remove end of thermocouple lead from thermocouple connection bushing and clean with fine sandpaper or emery cloth.
3.Authorized Service Agent Only: Pilot flame may be too high or too low. Adjust pilot flame adjustment screw so that pilot flame extends about
4.Check all connections for cleanliness and security.