Frymaster YSCFC24GSERIES manual Reverse the above steps for reassembly

Page 14

YSCFC SERIES FLATBOTTOM GAS FRYERS

CHAPTER 1: SERVICE PROCEDURES

5.Reverse the above steps for reassembly.

1.6.3 Replacing the Gas Valve

DANGER

Drain the frypot or remove drain valve handle to prevent accidental opening before

proceeding further.

1.Disconnect fryer from electrical and gas supplies.

2.Disconnect the wires from the gas valve terminal block, marking each wire to facilitate reconnections.

3.Remove the high-limit thermostat wire from the gas valve coil (CE only).

4.Remove gas lines and pipe union collars from the gas valve and remove the valve.

5.Remove the pipefitting from the old gas valve and install on the replacement valve, using Loctite PST567 or equivalent pipe thread sealant on threads. Do not apply sealant to the first two pipe threads. Doing so will clog and damage the gas valve.

6.Reverse steps 1-5 to install the replacement gas valve.

1.6.4Replacing Direct-Spark Ignitor Assembly (Units with Electronic Ignition Only)

1.Remove the burner shield from the burner-box slots.

2.Disconnect sense wire and ignition cable from the ignitor.

3.Remove the mounting screw from the ignitor mounting-bracket and remove the ignitor.

4.Reverse the procedure to replace the ignitor assembly. Ensure the ignitor is properly positioned in relation to the center burner before tightening mounting screw.

NOTE: The above procedure is applicable to fryers equipped with electronic ignition systems only.

Ensure ignitor is properly positioned (arrow) over the center burner prior to tightening the mounting screw.

1-9

Image 14 Contents
Hour Service Hotline YSCFC24G Series Flatbottom Gas FryersPage Computers Where Applicable FCC Yscfc Series Flatbottom Gas Fryers Table of Contents NON-CE Altitudes of 2000 feet or less Electronic Ignition ConfigurationFunctional Description Control Options Thermatron Controller BoardAccessing Fryers for Servicing Safety ComponentsCleaning the Gas Valve Vent Tube if applicable Adjusting Burner Manifold Gas Pressure Calibrating the Thermatron Temperature Controller Remove/Replace Temperature Probe or High-Limit Thermostat Replacing Fryer ComponentsTemperature probe High-limit Removing/Replacing Rocker Switches Reverse the above steps for reassembly Removing/Replacing Blower Assembly or Air Prover Switch Replacing the Frypot Frypot Baffle InspectionFrypot/Firebox Removal/Replacement Procedure Yscfc Series Flatbottom GAS Fryers Service Procedures If the Firebox Requires Replacement Troubleshooting and Problem Isolation Problems Related to the Electronic Circuits Ignition FailuresImproper Burner Functioning Yscfc Series Flatbottom GAS Fryers Service Procedures Improper Temperature Control Filtration ProblemsYscfc Series Flatbottom GAS Fryers Service Procedures Leakage Troubleshooting Guides Indicator Lights Light Indication Probable Cause Corrective ActionWiring Diagrams Wiring for Common Cabinet Flatbottom without Boil Out2 24/24 Filter Wiring 3 18/24 Common Cabinet Transformer Box Yscfc Series Flatbottom GAS Fryers Parts List Blower Assembly and Combustion AirBurner Manifold and Related Components Orifice Flue Caps, Top Caps, and Related Components Cover, 1824G Frypot use 106-2839SP for 2424G Frypot Cabinetry Oil Return Manifold Door Assemblies and Component Parts Control Panels, Wireways, and Related Components Control Panels, Wireways, and Related Components Oil SuctionOil Return and Suction Manifolds 810-3088Oil Return Manifold 106-5461Oil Return PlumbingFilter Unit Frypot, Drain, and Oil Return Components Firebox Assembly Drain Valve and Components Wiring Connectors, Pin Terminals, and Power Cords Connectors 2-Pin Female 6-Pin Female 9-Pin FemaleScrews, Nuts, and Fasteners Service Hotline