Frymaster YSCFC24GSERIES manual Yscfc Series Flatbottom GAS Fryers Service Procedures

Page 18

YSCFC SERIES FLATBOTTOM GAS FRYERS

CHAPTER 1: SERVICE PROCEDURES

6.Remove two screws securing topcap to wireway box. Remove topcap. Remove four screws securing wireway box to fryer cabinet (arrows) and carefully lower wireway box out of the way. Use care not to stretch or distort the wiring.

7.Remove two screws from the firebox heat shield (arrows), remove heat shield and set aside.

NOTE: Steps 8 and 9 must be performed prior to frypot removal, especially on systems with built-in filtration. Failure to perform these steps will make frypot removal extremely difficult, and cause possible damage to firebox components during removal.

8.Remove the burner box baffle by pushing the baffle up into the burner box until the baffle studs are clear of the slots. Tilt the baffle at an angle and remove it from the burner box.

9.Remove screws (two) securing the flame spreader to the burner box. Allow the spreader to drop down to clear the frypot baffles.

Remove topcap, wireway box and front heat shield to access firebox and frypot.

After removing burner-box baffle, remove screws (two) securing the flame spreader to the burner box. Allow the flame spreader to drop down in the burner box to clear the frypot baffles. Repeat for both sides.

1-13

Image 18 Contents
Hour Service Hotline YSCFC24G Series Flatbottom Gas FryersPage Computers Where Applicable FCC Yscfc Series Flatbottom Gas Fryers Table of Contents Electronic Ignition Configuration Functional DescriptionNON-CE Altitudes of 2000 feet or less Control Options Thermatron Controller BoardAccessing Fryers for Servicing Safety ComponentsCleaning the Gas Valve Vent Tube if applicable Adjusting Burner Manifold Gas PressureCalibrating the Thermatron Temperature Controller Remove/Replace Temperature Probe or High-Limit Thermostat Replacing Fryer ComponentsTemperature probe High-limit Removing/Replacing Rocker Switches Reverse the above steps for reassembly Removing/Replacing Blower Assembly or Air Prover Switch Replacing the Frypot Frypot Baffle InspectionFrypot/Firebox Removal/Replacement Procedure Yscfc Series Flatbottom GAS Fryers Service Procedures If the Firebox Requires Replacement Troubleshooting and Problem Isolation Problems Related to the Electronic Circuits Ignition FailuresImproper Burner Functioning Yscfc Series Flatbottom GAS Fryers Service Procedures Improper Temperature Control Filtration ProblemsYscfc Series Flatbottom GAS Fryers Service Procedures Leakage Troubleshooting Guides Indicator Lights Light Indication Probable Cause Corrective ActionWiring Diagrams Wiring for Common Cabinet Flatbottom without Boil Out2 24/24 Filter Wiring 3 18/24 Common Cabinet Transformer Box Yscfc Series Flatbottom GAS Fryers Parts List Blower Assembly and Combustion AirBurner Manifold and Related Components Orifice Flue Caps, Top Caps, and Related Components Cover, 1824G Frypot use 106-2839SP for 2424G Frypot Cabinetry Oil Return Manifold Door Assemblies and Component Parts Control Panels, Wireways, and Related Components Control Panels, Wireways, and Related Components Oil SuctionOil Return and Suction Manifolds 810-3088Oil Return Manifold 106-5461Oil Return PlumbingFilter Unit Frypot, Drain, and Oil Return Components Firebox Assembly Drain Valve and Components Wiring Connectors, Pin Terminals, and Power Cords Connectors 2-Pin Female 6-Pin Female 9-Pin FemaleScrews, Nuts, and Fasteners Service Hotline