CHAPTER 1: SERVICE PROCEDURES

1.6.6.2 Frypot/Firebox Removal/Replacement Procedure

1.Perform Procedure 1.6.5, Removing/Replacing Blower Assembly or Air Prover Switch, Steps 1 – 4.

2. Disconnect the union at the gas valve. Remove four bolts connecting the burner manifold brackets to the burner box. Remove the burner manifold assembly and set aside.

3. Mark and disconnect the drain-valve microswitch wiring. Remove elbow or drain-tee assembly, and then remove the drain valve/microswitch assembly.

Remove drain elbow and drain valve assembly from the frypot.

Disconnect union at gas valve and remove four bolts (two per side) to remove burner manifold.

Disconnect union at gas valve and remove four bolts connecting burner manifold brackets to firebox and drain valve assembly from frypot.

4.Remove two screws from control panel and lower, using care not to stretch or distort indicator light wiring (if applicable). If control panel is equipped with indicator lights, mark and disconnect wiring and set control panel aside.

If equipped with indicator lights, use a pin-pusher to remove pins from main-harness connector, and then remove control panel.

5.Perform Procedure 1.6.1, Remove/Replace Temperature Probe or High-Limit Thermostat, Steps 7 – 11.

1-12

Image 17 Contents
YSCFC24G Series Flatbottom Gas Fryers Hour Service HotlinePage Computers Where Applicable FCC Yscfc Series Flatbottom Gas Fryers Table of Contents NON-CE Altitudes of 2000 feet or less Electronic Ignition ConfigurationFunctional Description Thermatron Controller Board Control OptionsSafety Components Accessing Fryers for ServicingAdjusting Burner Manifold Gas Pressure Cleaning the Gas Valve Vent Tube if applicableCalibrating the Thermatron Temperature Controller Replacing Fryer Components Remove/Replace Temperature Probe or High-Limit ThermostatTemperature probe High-limit Removing/Replacing Rocker Switches Reverse the above steps for reassembly Removing/Replacing Blower Assembly or Air Prover Switch Frypot Baffle Inspection Replacing the FrypotFrypot/Firebox Removal/Replacement Procedure Yscfc Series Flatbottom GAS Fryers Service Procedures If the Firebox Requires Replacement Troubleshooting and Problem Isolation Ignition Failures Problems Related to the Electronic CircuitsImproper Burner Functioning Yscfc Series Flatbottom GAS Fryers Service Procedures Filtration Problems Improper Temperature ControlYscfc Series Flatbottom GAS Fryers Service Procedures Leakage Troubleshooting Guides Light Indication Probable Cause Corrective Action Indicator LightsWiring for Common Cabinet Flatbottom without Boil Out Wiring Diagrams2 24/24 Filter Wiring 3 18/24 Common Cabinet Transformer Box Blower Assembly and Combustion Air Yscfc Series Flatbottom GAS Fryers Parts ListBurner Manifold and Related Components Orifice Flue Caps, Top Caps, and Related Components Cover, 1824G Frypot use 106-2839SP for 2424G Frypot Cabinetry Oil Return Manifold Door Assemblies and Component Parts Control Panels, Wireways, and Related Components Control Panels, Wireways, and Related Components Suction Oil810-3088Oil Return Manifold 106-5461Oil Return Plumbing Oil Return and Suction ManifoldsFilter Unit Frypot, Drain, and Oil Return Components Firebox Assembly Drain Valve and Components Connectors 2-Pin Female 6-Pin Female 9-Pin Female Wiring Connectors, Pin Terminals, and Power CordsScrews, Nuts, and Fasteners Service Hotline