1.3 Cleaning the Gas Valve Vent Tube (if applicable)

1.Set the fryer power switch and the gas valve to the "OFF" position.

2.Carefully unscrew the vent tube from the gas valve. NOTE: The vent tube may be straightened for ease in removal.

3.Pass a piece of wire through the tube to remove any obstruction. Remove the wire and blow through the tube to ensure it is clear.

4.Reinstall tube and bend so that the opening is pointing downward.

1.4 Adjusting Burner Manifold Gas Pressure

WARNING

This task should be performed by qualified service personnel only.

1. Ensure that the gas valve knob is in the "OFF" position.

2. Remove the pressure tap plug from the burner manifold.

3. Insert the fitting for a gas pressure- measuring device into the pressure tap hole.

Remove pressure tap from burner manifold to check burner manifold pressure.

4.Place the gas valve in the "ON" position then place the fryer power switch in the "ON" position. When the burner lights and continues to burn, note gas pressure reading for correct pressure in accordance with the table on page 1-1.

1-4

Image 9 Contents
YSCFC24G Series Flatbottom Gas Fryers Hour Service HotlinePage Computers Where Applicable FCC Yscfc Series Flatbottom Gas Fryers Table of Contents Electronic Ignition Configuration Functional DescriptionNON-CE Altitudes of 2000 feet or less Thermatron Controller Board Control OptionsSafety Components Accessing Fryers for ServicingAdjusting Burner Manifold Gas Pressure Cleaning the Gas Valve Vent Tube if applicableCalibrating the Thermatron Temperature Controller Replacing Fryer Components Remove/Replace Temperature Probe or High-Limit ThermostatTemperature probe High-limit Removing/Replacing Rocker Switches Reverse the above steps for reassembly Removing/Replacing Blower Assembly or Air Prover Switch Frypot Baffle Inspection Replacing the FrypotFrypot/Firebox Removal/Replacement Procedure Yscfc Series Flatbottom GAS Fryers Service Procedures If the Firebox Requires Replacement Troubleshooting and Problem Isolation Ignition Failures Problems Related to the Electronic CircuitsImproper Burner Functioning Yscfc Series Flatbottom GAS Fryers Service Procedures Filtration Problems Improper Temperature ControlYscfc Series Flatbottom GAS Fryers Service Procedures Leakage Troubleshooting Guides Light Indication Probable Cause Corrective Action Indicator LightsWiring for Common Cabinet Flatbottom without Boil Out Wiring Diagrams2 24/24 Filter Wiring 3 18/24 Common Cabinet Transformer Box Blower Assembly and Combustion Air Yscfc Series Flatbottom GAS Fryers Parts ListBurner Manifold and Related Components Orifice Flue Caps, Top Caps, and Related Components Cover, 1824G Frypot use 106-2839SP for 2424G Frypot Cabinetry Oil Return Manifold Door Assemblies and Component Parts Control Panels, Wireways, and Related Components Control Panels, Wireways, and Related Components Suction Oil810-3088Oil Return Manifold 106-5461Oil Return Plumbing Oil Return and Suction ManifoldsFilter Unit Frypot, Drain, and Oil Return Components Firebox Assembly Drain Valve and Components Connectors 2-Pin Female 6-Pin Female 9-Pin Female Wiring Connectors, Pin Terminals, and Power CordsScrews, Nuts, and Fasteners Service Hotline