Frymaster 1824/2424G manual 24G Series Flatbottom GAS Fryers Service Procedures

Page 22

24G SERIES FLATBOTTOM GAS FRYERS CHAPTER 1: SERVICE PROCEDURES

6.Remove two screws securing topcap to wireway box. Remove topcap. Remove four screws securing wireway box to fryer cabinet (arrows) and carefully lower wireway box out of the way. Use care not to stretch or distort the wiring.

7.Remove two screws from the firebox heat shield (arrows), remove heat shield and set aside.

NOTE: Steps 8 and 9 must be performed prior to frypot removal, especially on systems with built-in filtration. Failure to perform these steps will make frypot removal extremely difficult, and cause possible damage to firebox components during removal.

8.Remove the burner box baffle by pushing the baffle up into the burner box until the baffle studs are clear of the slots. Tilt the baffle at an angle and remove it from the burner box.

9.Remove screws (two) securing the flame spreader to the burner box. Allow the spreader to drop down to clear the frypot baffles.

Remove topcap, wireway box and front heat shield to access firebox and frypot.

After removing burner-box baffle, remove screws (two) securing the flame spreader to the burner box. Allow the flame spreader to drop down in the burner box to clear the frypot baffles. Repeat for both sides.

1-17

Image 22
Contents Hour Service Hotline DEC 24G Series Flatbottom Gas FryersPage Computers Where Applicable FCC 24G Series Flatbottom Gas Fryers Table of Contents NON-CE Altitudes of 2000 feet or less Functional DescriptionCE only Altitudes of 2000 feet or less Pilot System Configuration Electronic Ignition ConfigurationControl Options Thermatron Controller Board Accessing Fryers for Servicing Safety ComponentsCleaning the Gas Valve Vent Tube if applicable Adjusting Burner Manifold Gas PressureAdjusting the Pilot Flame where applicable Calibrating the Thermatron Temperature ControllerLoosen two setscrews in dial arrows to recalibrate Remove/Replace Temperature Probe or High-Limit Thermostat Replacing Fryer ComponentsTemperature probe High-limit Removing/Replacing Rocker Switches 24G Series Flatbottom GAS Fryers Service Procedures Removing/Replacing Blower Assembly or Air Prover Switch Replacing air prover switch Replacing the Frypot Frypot Baffle InspectionFrypot/Firebox Removal/Replacement Procedure 24G Series Flatbottom GAS Fryers Service Procedures If the Firebox Requires Replacement Troubleshooting and Problem Isolation Problems Related to the Electronic Circuits Ignition FailuresImproper Burner Functioning 24G Series Flatbottom GAS Fryers Service Procedures Improper Temperature Control Filtration Problems24G Series Flatbottom GAS Fryers Service Procedures Leakage Troubleshooting Guides Temperature Power is present atTo temperature quickly Main Burner MalfunctionsIndicator Lights Light Indication Probable Cause Corrective ActionWiring Diagrams 10.2 24G Series Single Fryers, Non-CE with Boil-Out Switch 24G Series Flatbottom GAS Fryers Service Procedures 24G Series Flatbottom GAS Fryers Service Procedures 24G Series Flatbottom GAS Fryers Service Procedures 24G Series Flatbottom GAS Fryers Service Procedures 24G Series Flatbottom GAS Fryers Service Procedures Single Fryers CE-Approved 10.8 24G SeriesWiring, Standing Pilot Scfc Models 10.10 24GTI Oil Return/Filter System 24G Series Flatbottom GAS Fryers Parts List Blower Assembly and Combustion AirBurner Manifold and Related Components Component Flue Caps, Top Caps, and Related Components 2424G Notched Left End use 823-4058 for notched right end Common Cabinet Components Scfc Models Cabinetry Scfc ModelsNot illustrated Door Assemblies and Component Parts Scfc Models Control Panels, Wireways, and Related Components Scfc Models Component Oil Return and Suction Manifolds Scfc Models Component Filter Unit Scfc Models Frypot, Drain, and Oil Return Components Scfc Models 24G Series Flatbottom GAS Fryers Parts List Previous Style SCF Models Cabinetry SCF ModelsBack, Single Fryer Cabinet Door Assemblies and Component Parts SCF Models Control Panels, Wireways, and Related Components SCF Models Not illustrated Oil Return and Suction Manifolds SCF Models Component 24G Series Flatbottom GAS Fryers Parts List Filter Unit SCF Models Caster, 2-inch Rigid use 810-2805 for 2-inch Swivel CasterFrypot, Drain, and Oil Return Components SCF Models Component Drain Valve and Components Wiring Connectors, Pin Terminals, and Power Cords Connectors 2-Pin Female 6-Pin Female 9-Pin FemaleScrews, Nuts, and Fasteners Appendix ND90 Built-In Filter System Components Line Parts Pump, 5GPM use 810-2098 for 8GPM Pump Seal, Shaft O-Ring Service Hotline