Frymaster 1824/2424G manual Not illustrated

Page 63

24G SERIES FLATBOTTOM GAS FRYERS

CHAPTER 2: PARTS LIST

2.5.3 Control Panels, Wireways, and Related Components – SCF Models (cont.)

ITEM PART #

1106-0882

2824-1140

3823-4001

4200-3167

5807-1597

6807-1321

7807-3536

8816-0217

9810-1164

11 810-0045

12 807-2469

13 810-0678

14 807-0125

15 200-1671

16 826-1680

17 807-3559

18 807-0800

19 106-2058SP

20 807-3611

21 807-3640

22 807-3613

23 200-1337

24 106-1966

25 816-0220

26 807-2103

27 106-2775

28 200-4719

29 826-2086

30 210-3275

31 802-2134

32 816-0534

33 210-1985

34 820-0136

35 820-0135

36 210-3754

37 210-2716

38 807-3574

39 807-3576

40 807-3580

41 106-1978

42 106-4686

43 200-4602

44 210-2689

45 802-2085

46 200-3901

47200-3356

* 807-3577

*Not illustrated.

COMPONENT

Probe, Thermostat Assembly, bottom 62.5” with connector (use 106-2607SP for 20” Top) Vent, 1824G Wireway (use 824-1139 for 2424G)

Box, 1824G Wireway (use 823-4000 for 2425G) Box, Remote Thermatron Adapter

Fuse, 3-amp Slow-Blow

Holder, Panel-Mount Fuse

Potentiometer, Temperature Control with spade terminals Paper, Terminal Block Insulating

Terminal Block, 1-Piece Screwless Bushing. .875-inch

Bushing, 1-inch Bushing, .375-inch Bushing, .50-inch Cover, Thermostat Entry Clamp, Plastic Wire (Pkg. of 8)

Thermostat, 435°F High-Limit w/Manual Reset (use 807-3560 for 210°C CE units) Transformer, Filter 120V/24V 50/60Hz 50VA

Relay Assembly, Boil-Out and Latch (use 106-1648SP for Bracket Switch Assembly) Relay, Latch/Filter 24VAC Coil (Left Relay) (use 807-4114 for models after Oct 04) Relay, Boil Out 120VAC Coil (Right Relay)

Spring, Relay Retaining Bracket, Oil Return Relay

Socket Assembly, 24V Oil Return Relay (use 807-3612 for Relay Socket only) Insulation, Microswitch

Microswitch, Straight Lever

Plate Assembly, Microswitch Adjustment Plate, Interface Board Mounting Thermatron Board, 115/230V

Faceplate, 1824G Thermatron Blank (use 210-3168 for 2424G) Label, Thermatron Faceplate

Knob, Thermatron Control

Faceplate, Single Fryer Thermatron Blank

Faceplate with Label, Old-Style Single Fryer 5.17” H x 4.04” W Faceplate with Label, Old-Style SCF 3.13” H x 6.38” W Control Panel, 1824G Two-Switch (use 210-4977 for 2424G) Control Panel, 1824G Two-Lamp (use 210-2652 for 2424G) Switch, Power ON/OFF Rocker

Switch, Momentary Reset Switch, Boil-Out

Lamp Assembly, Red 120V 807-3581 lamp only (106-4687230/250V)(106-4730 24V white) Lamp Assembly, Green 120V 807-3582 lamp only (106-4686230/250V)(106-4729 24V) Box, Single Fryer Control

Plate, Single Fryer Control Panel

Label, Single Fryer Control Panel

Lid, Single Fryer Control Box

Cover, Single Fryer Control Box Access

Circuit Breaker, 7 amp

2-20

Image 63
Contents 24G Series Flatbottom Gas Fryers Hour Service Hotline DECPage Computers Where Applicable FCC 24G Series Flatbottom Gas Fryers Table of Contents Functional Description NON-CE Altitudes of 2000 feet or lessCE only Altitudes of 2000 feet or less Electronic Ignition Configuration Pilot System ConfigurationControl Options Thermatron Controller Board Safety Components Accessing Fryers for ServicingAdjusting Burner Manifold Gas Pressure Cleaning the Gas Valve Vent Tube if applicableCalibrating the Thermatron Temperature Controller Adjusting the Pilot Flame where applicableLoosen two setscrews in dial arrows to recalibrate Replacing Fryer Components Remove/Replace Temperature Probe or High-Limit ThermostatTemperature probe High-limit Removing/Replacing Rocker Switches 24G Series Flatbottom GAS Fryers Service Procedures Removing/Replacing Blower Assembly or Air Prover Switch Replacing air prover switch Frypot Baffle Inspection Replacing the FrypotFrypot/Firebox Removal/Replacement Procedure 24G Series Flatbottom GAS Fryers Service Procedures If the Firebox Requires Replacement Troubleshooting and Problem Isolation Ignition Failures Problems Related to the Electronic CircuitsImproper Burner Functioning 24G Series Flatbottom GAS Fryers Service Procedures Filtration Problems Improper Temperature Control24G Series Flatbottom GAS Fryers Service Procedures Leakage Troubleshooting Guides Main Burner Malfunctions Power is present atTo temperature quickly TemperatureLight Indication Probable Cause Corrective Action Indicator LightsWiring Diagrams 10.2 24G Series Single Fryers, Non-CE with Boil-Out Switch 24G Series Flatbottom GAS Fryers Service Procedures 24G Series Flatbottom GAS Fryers Service Procedures 24G Series Flatbottom GAS Fryers Service Procedures 24G Series Flatbottom GAS Fryers Service Procedures 24G Series Flatbottom GAS Fryers Service Procedures 10.8 24G Series Single Fryers CE-ApprovedWiring, Standing Pilot Scfc Models 10.10 24GTI Oil Return/Filter System Blower Assembly and Combustion Air 24G Series Flatbottom GAS Fryers Parts ListBurner Manifold and Related Components Component Flue Caps, Top Caps, and Related Components 2424G Notched Left End use 823-4058 for notched right end Cabinetry Scfc Models Common Cabinet Components Scfc ModelsNot illustrated Door Assemblies and Component Parts Scfc Models Control Panels, Wireways, and Related Components Scfc Models Component Oil Return and Suction Manifolds Scfc Models Component Filter Unit Scfc Models Frypot, Drain, and Oil Return Components Scfc Models 24G Series Flatbottom GAS Fryers Parts List Cabinetry SCF Models Previous Style SCF ModelsBack, Single Fryer Cabinet Door Assemblies and Component Parts SCF Models Control Panels, Wireways, and Related Components SCF Models Not illustrated Oil Return and Suction Manifolds SCF Models Component 24G Series Flatbottom GAS Fryers Parts List Caster, 2-inch Rigid use 810-2805 for 2-inch Swivel Caster Filter Unit SCF ModelsFrypot, Drain, and Oil Return Components SCF Models Component Drain Valve and Components Connectors 2-Pin Female 6-Pin Female 9-Pin Female Wiring Connectors, Pin Terminals, and Power CordsScrews, Nuts, and Fasteners Appendix ND90 Built-In Filter System Components Line Parts Pump, 5GPM use 810-2098 for 8GPM Pump Seal, Shaft O-Ring Service Hotline