1.3 Cleaning the Gas Valve Vent Tube (if applicable)

1.Set the fryer power switch and the gas valve to the "OFF" position.

2.Carefully unscrew the vent tube from the gas valve. NOTE: The vent tube may be straightened for ease in removal.

3.Pass a piece of wire through the tube to remove any obstruction. Remove the wire and blow through the tube to ensure it is clear.

4.Reinstall tube and bend so that the opening is pointing downward.

1.4 Adjusting Burner Manifold Gas Pressure

WARNING

This task should be performed by qualified service personnel only.

1. Ensure that the gas valve knob is in the "OFF" position.

2. Remove the pressure tap plug from the burner manifold.

3. Insert the fitting for a gas pressure- measuring device into the pressure tap hole.

Remove pressure tap from burner manifold to check burner manifold pressure.

4.Place the gas valve in the "ON" position then place the fryer power switch in the "ON" position. When the burner lights and continues to burn, note gas pressure reading for correct pressure in accordance with the table on page 1-1.

1-6

Image 11
Contents 24G Series Flatbottom Gas Fryers Hour Service Hotline DECPage Computers Where Applicable FCC 24G Series Flatbottom Gas Fryers Table of Contents CE only Altitudes of 2000 feet or less Functional DescriptionNON-CE Altitudes of 2000 feet or less Electronic Ignition Configuration Pilot System ConfigurationControl Options Thermatron Controller Board Safety Components Accessing Fryers for ServicingAdjusting Burner Manifold Gas Pressure Cleaning the Gas Valve Vent Tube if applicableCalibrating the Thermatron Temperature Controller Adjusting the Pilot Flame where applicableLoosen two setscrews in dial arrows to recalibrate Replacing Fryer Components Remove/Replace Temperature Probe or High-Limit ThermostatTemperature probe High-limit Removing/Replacing Rocker Switches 24G Series Flatbottom GAS Fryers Service Procedures Removing/Replacing Blower Assembly or Air Prover Switch Replacing air prover switch Frypot Baffle Inspection Replacing the FrypotFrypot/Firebox Removal/Replacement Procedure 24G Series Flatbottom GAS Fryers Service Procedures If the Firebox Requires Replacement Troubleshooting and Problem Isolation Ignition Failures Problems Related to the Electronic CircuitsImproper Burner Functioning 24G Series Flatbottom GAS Fryers Service Procedures Filtration Problems Improper Temperature Control24G Series Flatbottom GAS Fryers Service Procedures Leakage Troubleshooting Guides Main Burner Malfunctions Power is present atTo temperature quickly TemperatureLight Indication Probable Cause Corrective Action Indicator LightsWiring Diagrams 10.2 24G Series Single Fryers, Non-CE with Boil-Out Switch 24G Series Flatbottom GAS Fryers Service Procedures 24G Series Flatbottom GAS Fryers Service Procedures 24G Series Flatbottom GAS Fryers Service Procedures 24G Series Flatbottom GAS Fryers Service Procedures 24G Series Flatbottom GAS Fryers Service Procedures 10.8 24G Series Single Fryers CE-ApprovedWiring, Standing Pilot Scfc Models 10.10 24GTI Oil Return/Filter System Blower Assembly and Combustion Air 24G Series Flatbottom GAS Fryers Parts ListBurner Manifold and Related Components Component Flue Caps, Top Caps, and Related Components 2424G Notched Left End use 823-4058 for notched right end Cabinetry Scfc Models Common Cabinet Components Scfc ModelsNot illustrated Door Assemblies and Component Parts Scfc Models Control Panels, Wireways, and Related Components Scfc Models Component Oil Return and Suction Manifolds Scfc Models Component Filter Unit Scfc Models Frypot, Drain, and Oil Return Components Scfc Models 24G Series Flatbottom GAS Fryers Parts List Cabinetry SCF Models Previous Style SCF ModelsBack, Single Fryer Cabinet Door Assemblies and Component Parts SCF Models Control Panels, Wireways, and Related Components SCF Models Not illustrated Oil Return and Suction Manifolds SCF Models Component 24G Series Flatbottom GAS Fryers Parts List Caster, 2-inch Rigid use 810-2805 for 2-inch Swivel Caster Filter Unit SCF ModelsFrypot, Drain, and Oil Return Components SCF Models Component Drain Valve and Components Connectors 2-Pin Female 6-Pin Female 9-Pin Female Wiring Connectors, Pin Terminals, and Power CordsScrews, Nuts, and Fasteners Appendix ND90 Built-In Filter System Components Line Parts Pump, 5GPM use 810-2098 for 8GPM Pump Seal, Shaft O-Ring Service Hotline