Jenn-Air W10436037B Complete Installation, If you need Assistance or Service

Page 10

3-Wire Cable from Home Power Supply to 4-Wire Cable from Cooktop - U.S. only

IMPORTANT: Use the 3-wire cable from power supply where local codes permit connecting the frame-ground conductor to the neutral (white) junction box wire.

A

E

B

F

G

H

C

I

D

A. Cable from home power supply

F. White wire

B. Red wires

G. UL listed wire connector

C. White wire and green (or bare)

H. Black wires

wire (from cooktop)

I. UL listed or CSA approved

D. 4-wire cable from cooktop

conduit connector

E. Junction box

 

1.Connect the 2 black wires together using the UL listed wire connectors.

2.Connect the 2 red wires together using the UL listed wire connectors.

3.Connect the green or bare and white cooktop cable wires to the white (neutral) wire in the junction box using the UL listed wire connectors.

4.Install junction box cover.

Complete Installation

1.Check that all parts are now installed. If there is an extra part, go back through the steps to see which step was skipped.

2.Check that you have all your tools.

3.Dispose of/recycle all packaging materials.

4.Use a mild solution of liquid household cleaner and warm water to clean cooktop before use. Dry thoroughly with a soft cloth. For more information, see the “Cooktop Care” section of the Use and Care Guide.

5.Read “Cooktop Use” in the cooktop Use and Care Guide.

6.Reconnect power.

7.Use the Flow Tester Card provided with your cooktop to check the airflow (see card for step-by-step instructions).

NOTE: If the cooktop does not work after turning on the power, check that a circuit breaker has not tripped or a household fuse has not blown. See “Troubleshooting” section in the Use and Care Guide for further information.

If you need Assistance or Service:

Please reference the “Assistance or Service” section of the Use and Care Guide or contact the dealer from whom you purchased your cooktop.

10

Image 10
Contents 30 76.2 CM and 36 91.4 CM Electric Installation Requirements Cooktop SafetyTools and Parts Location Requirements 36 91.4 cm Cooktop for standard and electric modelsCutout Dimensions Cabinet DimensionsVenting Requirements Option 1 Roof Venting Option 2 Wall Venting Venting MethodsFor Best Performance Makeup AirCalculating Vent System Length Concrete Slab Installations Exhaust Through WallJenn-AirDuct Free Filter Accessory Kit Example vent systemPrepare Cooktop Installation InstructionsElectrical Requirements Before You Make the Electrical ConnectionRotate Blower Optional Install Foam StripInstall Cooktop To rotate blowerMake Electrical Connection If your home has You will be Go to Section Connecting toElectrical Connection Options Complete Installation If you need Assistance or ServiceSécurité DE LA Table DE Cuisson Exigences DinstallationOutillage et pièces Exigences demplacement Dimensions du placard Dimensions de l’ouverture à découperPour obtenir la meilleure performance Installations pour régions à climat froidExigences concernant lévacuation Air d’appointTrousse accessoire de filtration sans conduit Jenn-Air Méthodes dévacuationExemple de circuit dévacuation Spécifications électriquesCalcul de la longueur effective du circuit dévacuation Composant Conduit de diamètre de 15,2 cm Coude à Pi 0,8 mPréparation de la table de cuisson Instructions D’INSTALLATIONInstallation de la bande de mousse Avant d’établir la connexion électriqueRotation du ventilateur Facultative Installation de la table de cuissonPour faire pivoter le ventilateur Câblage de la maison Point de Raccordement électriqueOptions de raccordement électrique Distribution SuivanteAchever linstallation Si vous avez besoin dassistance ou de service