Jenn-Air W10436037B Make Electrical Connection, Electrical Connection Options

Page 9

Make Electrical Connection

WARNING

Electrical Shock Hazard

Disconnect power before servicing.

Use 8 gauge copper wire.

Electrically ground cooktop.

Failure to follow these instructions can result in death, fire, or electrical shock.

This cooktop is manufactured with the frame connected to the bare ground wire. Connect the cooktop cable to the junction box through the UL listed or CSA approved conduit connector.

1.Disconnect power.

2.Remove junction box cover, if present.

3.Connect the flexible cable conduit from the cooktop to the junction box using a UL listed or CSA approved conduit connector.

4.Tighten screws on conduit connector if present.

5.See the “Electrical Connection Options” chart to complete installation for your type of electrical connection.

Electrical Connection Options

If your home has:

And you will be

Go to Section:

 

connecting to:

 

4-wire

A fused

4-Wire Cable from

 

disconnect or

Power Supply

 

circuit breaker

 

 

box

 

½"

 

 

(1.3 cm)

 

 

4-Wire Cable from Home Power Supply to 4-Wire Cable from Cooktop

IMPORTANT: Use the 4-wire cable from home power supply in the U.S. where local codes do not allow grounding through neutral, new branch circuit installations (1996 NEC), mobile homes and recreational vehicles, new construction, and in Canada.

A

 

B

E

 

 

 

 

 

 

F

 

 

 

G

 

 

 

C

H

D

I

A. Cable from home power supply

F. White wires

B. Black wires

G. UL listed wire connector

C. Bare ground wires

H. Red wires

D. 4-wire cable from cooktop

I. UL listed or CSA approved

E. Junction box

conduit connector

1.Connect the 2 black wires together using the UL listed wire connectors.

2.Connect the 2 red wires together using the UL listed wire connectors.

3.Connect the 2 white wires together using the UL listed wire connectors.

4.Connect the green (or bare) ground wire from the cooktop cable to the green (or bare) ground wire (in the junction box) using the UL listed wire connectors.

5.Install junction box cover.

3-wire

A fused

3-Wire Cable from

 

disconnect or

Power Supply

 

circuit breaker

 

 

box

 

 

½"

 

 

(1.3 cm)

 

9

Image 9
Contents 30 76.2 CM and 36 91.4 CM Electric Cooktop Safety Installation RequirementsTools and Parts 36 91.4 cm Cooktop for standard and electric models Location RequirementsCabinet Dimensions Cutout DimensionsVenting Requirements For Best Performance Venting MethodsOption 1 Roof Venting Option 2 Wall Venting Makeup AirJenn-AirDuct Free Filter Accessory Kit Concrete Slab Installations Exhaust Through WallCalculating Vent System Length Example vent systemElectrical Requirements Installation InstructionsPrepare Cooktop Before You Make the Electrical ConnectionInstall Cooktop Install Foam StripRotate Blower Optional To rotate blowerIf your home has You will be Go to Section Connecting to Make Electrical ConnectionElectrical Connection Options If you need Assistance or Service Complete InstallationExigences Dinstallation Sécurité DE LA Table DE CuissonOutillage et pièces Exigences demplacement Dimensions de l’ouverture à découper Dimensions du placardExigences concernant lévacuation Installations pour régions à climat froidPour obtenir la meilleure performance Air d’appointMéthodes dévacuation Trousse accessoire de filtration sans conduit Jenn-AirCalcul de la longueur effective du circuit dévacuation Spécifications électriquesExemple de circuit dévacuation Composant Conduit de diamètre de 15,2 cm Coude à Pi 0,8 mInstallation de la bande de mousse Instructions D’INSTALLATIONPréparation de la table de cuisson Avant d’établir la connexion électriqueInstallation de la table de cuisson Rotation du ventilateur FacultativePour faire pivoter le ventilateur Options de raccordement électrique Raccordement électriqueCâblage de la maison Point de Distribution SuivanteSi vous avez besoin dassistance ou de service Achever linstallation