Location Requirements

IMPORTANT: Observe all governing codes and ordinances. When installing cooktop, use minimum dimensions given.

To eliminate the risk of burns or fire by reaching over the heated surface units, cabinet storage space located above the surface units should be avoided. If cabinet storage is to be provided, the risk can be reduced by installing a range hood that projects horizontally a minimum of 5" (12.7 cm) beyond the bottom of the cabinets.

Use the countertop opening dimensions that are given with these Installation Instructions. Given dimensions are minimum clearances and provide 0" (0 cm) clearance.

Grounded electrical supply is required. See “Electrical Requirements” section.

If cabinet has drawers, drawers will need to be removed and drawer fronts installed on front of cabinet.

IMPORTANT: An under-counter built-in oven cannot be installed under this product.

36" (91.4 cm) Cooktop - for standard and electric models

C

B

A

A. Model/serial rating plate location

B. 20⁹⁄₁₆" (52.3 cm)

C. 22" (55.9 cm)

Product Dimensions

A

30" (76.2 cm) Cooktop - for standard and electric models

B

H

G

C

B

F

EC

AD

A. Model/serial rating plate location

B. 20⁹⁄₁₆" (52.3 cm)

C. 22" (55.9 cm)

A

B

H

G

F

 

E

C

D

 

A. 29³⁄₄" (75.6 cm)

E. 12¹⁄₂" (31.8 cm)

B. 12¹⁄₂" (31.8 cm)

F. 2" (5.1 cm) recommended minimum

centerline of product to

cabinet to motor clearance

edge of burner box

G. 18" (45.7 cm)

C. 12¹⁄₂" (31.8 cm)

H. 4⁵⁄₈" (11.8 cm)

D. 28³⁄₈" (72.1 cm)

 

A. 35¹¹⁄₃₂" (89.8 cm)

B. 16¹⁵⁄₆₄" (41.2 cm) centerline of product to edge of burner box

C. 12⁷⁄₈" (32.8 cm) D. 34¹⁄₈" (86.7 cm)

E. 12¹⁄₂" (31.8 cm)

F.8¹⁷⁄₆₄" (20.9 cm) recommended minimum cabinet to motor clearance

G. 18" (45.7 cm)

H. 4⁵⁄₈" (11.8 cm)

3

Image 3
Contents 30 76.2 CM and 36 91.4 CM Electric Cooktop Safety Installation RequirementsTools and Parts 36 91.4 cm Cooktop for standard and electric models Location RequirementsCabinet Dimensions Cutout DimensionsVenting Requirements Makeup Air Venting MethodsFor Best Performance Option 1 Roof Venting Option 2 Wall VentingExample vent system Concrete Slab Installations Exhaust Through WallJenn-AirDuct Free Filter Accessory Kit Calculating Vent System LengthBefore You Make the Electrical Connection Installation InstructionsElectrical Requirements Prepare CooktopTo rotate blower Install Foam StripInstall Cooktop Rotate Blower OptionalIf your home has You will be Go to Section Connecting to Make Electrical ConnectionElectrical Connection Options If you need Assistance or Service Complete InstallationExigences Dinstallation Sécurité DE LA Table DE CuissonOutillage et pièces Exigences demplacement Dimensions de l’ouverture à découper Dimensions du placardAir d’appoint Installations pour régions à climat froidExigences concernant lévacuation Pour obtenir la meilleure performanceMéthodes dévacuation Trousse accessoire de filtration sans conduit Jenn-AirComposant Conduit de diamètre de 15,2 cm Coude à Pi 0,8 m Spécifications électriquesCalcul de la longueur effective du circuit dévacuation Exemple de circuit dévacuationAvant d’établir la connexion électrique Instructions D’INSTALLATIONInstallation de la bande de mousse Préparation de la table de cuissonInstallation de la table de cuisson Rotation du ventilateur FacultativePour faire pivoter le ventilateur Distribution Suivante Raccordement électriqueOptions de raccordement électrique Câblage de la maison Point deSi vous avez besoin dassistance ou de service Achever linstallation