Jenn-Air W10436037B Concrete Slab Installations Exhaust Through Wall, Example vent system

Page 6

Concrete Slab Installations - Exhaust Through Wall

B

AD

NC

M

L

 

K

 

 

 

E

F G

H

I

J

6" (15.2 cm) to 3¹⁄₄" x 10"

1 ft

(8.3 cm x 25.4 cm) transition

(0.3 m)

 

 

3¹⁄₄" x 10" (8.3 cm x 25.4 cm)

5.0 ft

to 6" (15.2 cm) 90° elbow

(1.5 m)

transition

 

 

 

6" (15.2 cm) to 3¹⁄₄" x 10"

5.0 ft

(8.3 cm x 25.4 cm) 90° elbow

(1.5 m)

transition

 

A. Wall cap

B. 6" (15.2 cm) round metal vent C. 16" (40.6 cm) maximum

D. 6" (15.2 cm) round PVC sewer pipe E. 6" (15.2 cm) round metal vent

F. 6" (15.2 cm) round PVC coupling G. Concrete slab

H. 6" (15.2 cm) round PVC sewer pipe

I. 6" (15.2 cm) round 90° PVC sewer pipe elbow

J. Tightly pack gravel or sand completely around pipe. K. 30 ft (9.1 m) max.

L. 6" (15.2 cm) round 90° PVC sewer pipe elbow M. 6" (15.2 cm) round PVC coupling

N. 12" (30.5 cm) minimum

3¹⁄₄" x 10" (8.3 cm x 25.4 cm)

5.0 ft

90° elbow

(1.5 m)

 

 

 

 

 

 

 

 

 

 

 

 

3¹⁄₄" x 10" (8.3 cm x 25.4 cm)

12.0 ft

flat elbow

(3.7 m)

 

 

 

 

 

 

 

 

 

 

 

 

 

3¹⁄₄" x 10" (8.3 cm x 25.4 cm)

0.0 ft

wall cap

(0.0 m)

Jenn-Air®Duct Free Filter Accessory Kit

(For model numbers JED3430, JED3536, JED4430, JED4536, JGD3430 and JGD3536)

On select downdraft models, the Jenn-Air®Duct Free Filter Accessory Kit Part Number JDA7000WX is now available. The Jenn-Air®Duct Free Filter Accessory Kit is ideal for both new construction and kitchen renovation projects because it provides an easy alternative to the installation of metal ducting and venting in the downdraft system outside the home. The kit includes all required hardware, one filter and complete installation instructions. For more information on the Jenn-Air®Duct Free Filter Accessory Kit, contact your Jenn-Air dealer or call 1-800-JENNAIR (1-800-536-6247).

Calculating Vent System Length

To calculate the length of the system you need, add the equivalent feet (meters) for each vent piece used in the system.

Vent Piece

6" (15.2 cm) Round

45° elbow

2.5 ft

 

(0.8 m)

 

 

90° elbow

5.0 ft

 

(1.5 m)

 

 

6" (15.2 cm)

0.0 ft

wall cap

(0.0 m)

 

 

3¹⁄₄" x 10" (8.3 cm x 25.4 cm)

4.5 ft

to 6" (15.2 cm) transition

(1.4 m)

Example vent system

wall cap

90˚ elbow

6 ft (1.8 m)

2ft

(0.6 m)

1- 90° elbow

= 5 ft (1.5 m)

8 ft (2.4 m) straight

= 8 ft (2.4 m)

1 - wall cap

= 0 ft (0 m)

 

 

System length

= 13 ft (3.9 m)

NOTE: Flexible vent is not recommended. Flexible vent creates back pressure and air turbulence that greatly reduce performance.

6

Image 6
Contents 30 76.2 CM and 36 91.4 CM Electric Cooktop Safety Installation RequirementsTools and Parts Location Requirements 36 91.4 cm Cooktop for standard and electric modelsCabinet Dimensions Cutout DimensionsVenting Requirements Option 1 Roof Venting Option 2 Wall Venting Venting MethodsFor Best Performance Makeup AirCalculating Vent System Length Concrete Slab Installations Exhaust Through WallJenn-AirDuct Free Filter Accessory Kit Example vent systemPrepare Cooktop Installation InstructionsElectrical Requirements Before You Make the Electrical ConnectionRotate Blower Optional Install Foam StripInstall Cooktop To rotate blowerIf your home has You will be Go to Section Connecting to Make Electrical ConnectionElectrical Connection Options Complete Installation If you need Assistance or ServiceExigences Dinstallation Sécurité DE LA Table DE CuissonOutillage et pièces Exigences demplacement Dimensions du placard Dimensions de l’ouverture à découperPour obtenir la meilleure performance Installations pour régions à climat froidExigences concernant lévacuation Air d’appointTrousse accessoire de filtration sans conduit Jenn-Air Méthodes dévacuationExemple de circuit dévacuation Spécifications électriquesCalcul de la longueur effective du circuit dévacuation Composant Conduit de diamètre de 15,2 cm Coude à Pi 0,8 mPréparation de la table de cuisson Instructions D’INSTALLATIONInstallation de la bande de mousse Avant d’établir la connexion électriqueInstallation de la table de cuisson Rotation du ventilateur FacultativePour faire pivoter le ventilateur Câblage de la maison Point de Raccordement électriqueOptions de raccordement électrique Distribution SuivanteAchever linstallation Si vous avez besoin dassistance ou de service