Bloomfield WV-2HFGRWT, WV-2HSG Ventilator Section Cleaning Instructions, Preparation, Tools

Page 20

CLEANING INSTRUCTIONS

CAUTION:

ELECTRIC

SHOCK HAZARD

Disconnect appliance from electric power before cleaning.

CAUTION:

HOT SURFACE

Exposed surfaces

can be hot to the touch

and may cause burns. Allow appliance to cool before cleaning.

IMPORTANT:

Never allow PRE-FILTER or FILTER PACK to get wet. DO NOT wash either of these two filters. Washing these filters will ruin them and cause the appliance to shut-down.

IMPORTANT:

DO NOT spill or pour water into controls, control panel, wiring or coil-type hotplate elements. Damage to internal components will occur. Damage to internal components from water damage is not covered by warranty.

IMPORTANT:

This appliance is not jet stream approved. Do not direct water jet or steam jet at this appliance, or at any control panel or wiring.

Do not splash or pour water on, in or over any controls, control panel or wiring.

IMPORTANT:

DO NOT use steel wool or metal implements to clean drawers or cabinet surfaces.

VENTILATOR SECTION CLEANING INSTRUCTIONS

PREPARATION

Disconnect appliance from electric power

Allow to cool before cleaning

FREQUENCY Weekly

TOOLS

Warm water and a mild detergent

Soft clean cloth or sponge

Bristle brush

Container for disposal of grease

CLEANING

Disconnect appliance from electric power Allow to cool before cleaning

Remove the grease baffle, pre-filter assembly, grease trough and grease cup. Empty the grease trough and grease cup.

Remove the pre-filter from the filter frame. Wash and rinse the filter frame ONLY.

Wash and rinse the grease baffle, grease trough and grease cup in a sink or dishwasher using mild detergent and warm water. Allow to air dry.

Reinsert the pre-filter into the filter frame. Reinstall the pre-filter, grease baffle, grease trough and grease cup.

Procedure is complete

508 p/n 304456 OpManual WV-2H Series Ventless Combo Cook Center

18

Image 20
Contents 508 Important do not Discard this ManualPage Introduction Back Side Bottom TOPVentilator Section Operating Features & Controls Ventilator Section Description CommentVentilator Section Controls & Indicator Lights Optional Drawer Warmer Section Ventilator Section ControlsGriddle Section Hotplate Section Fire Hazard Electric Shock HazardRisk Damage HOT SurfaceVentilator Indicators Installation SetupUnpacking & Inspection Risk InjuryPage Fire Suppression System Installation Authority Having JurisdictionInstallation Grease Drip Tray Installation Roll Warmer Drawer InstallationDo not Operate Unless the Grease Drip Tray is Installed Burn HazardPRE-FILTER Element OperationVentilator Operation Using the Griddle Griddle Operation Preparing the Griddle SurfaceSeasoning Standard Griddles Chrome Plated GriddlesOperating Chart for Drawer Warmers Heating OptionsItem Description RWT- Control Module SET Setpoint TemperatureChange Display Mode ºF or ºC Cleaning Instructions Ventilator Section Cleaning InstructionsCleaning PreparationHot Surface Hotplate SectionFrequency Daily Griddle Cleaning Instructions PrecautionsElectrical Shock Hazard Heat Smoke HazardDrawer Warmer Cleaning Instructions PrecautionsFrequency ToolsHOT Surface Adjustments and LubricationShock Hazard Symptom Possible Cause Recommended Remedy Maintenance Schedules Fire HazardWells BLOOMFIELD, LLC Wells BLOOMFIELD, LLC Ansul Health Hazards Wells Bloomfield, LLC Genuin e Parts

WV-2HFGRW, WV-2HFG, WV-2HSGRW, WV-2HFGRWT, WV-2HSGRWT specifications

Bloomfield WV-2HSG, WV-2HSGRWT, WV-2HSGRW, WV-2HFGRW, and WV-2HFGRWT are innovative technologies designed to enhance various sectors, particularly in the fields of heating, ventilation, and air conditioning (HVAC). These models are recognized for their efficiency, versatility, and advanced features, making them popular choices among homeowners and professionals alike.

One of the standout features of the Bloomfield WV-2HSG series is its energy efficiency. These units are designed to consume less energy while providing maximum output, helping users save on utility bills without sacrificing comfort. The incorporation of environmentally friendly refrigerants also aligns with modern sustainability goals, reducing the overall carbon footprint of these systems.

The WV-2HSG model is particularly noted for its superior heating capabilities, which are ideal for colder climates. Its cutting-edge heat exchange technology ensures rapid heating and consistent temperature regulation throughout the space. This model is equipped with a user-friendly control interface, allowing for easy adjustments and programming of heating cycles to suit different preferences and schedules.

In contrast, the WV-2HSGRWT and WV-2HSGRW models emphasize adaptability in various humidity and air quality conditions. These systems feature advanced humidity sensors that monitor indoor conditions and automatically adjust operations to maintain a comfortable atmosphere. This is especially beneficial for areas prone to high humidity levels, as it prevents mold growth and promotes healthier living environments.

The WV-2HFGRW and WV-2HFGRWT variants stand out with their innovative filtration systems, which capture airborne particles, allergens, and contaminants. These models integrate HEPA filters coupled with activated carbon layers, ensuring clean and pure air circulation within the home. This characteristic is particularly appealing to individuals with allergies or respiratory issues, as it enhances overall indoor air quality.

All models within this range come equipped with smart technology integrations, enabling remote operation through smartphones and smart home systems. This not only adds convenience for users but also allows for monitoring and managing energy consumption effectively. Together, these features position the Bloomfield WV-2HSG series as exemplary products in the HVAC industry, merging efficiency, functionality, and cutting-edge technology to meet the needs of modern consumers.